2 mounting instructions – KROHNE OPTISWITCH 5100C Namur EN User Manual

Page 13

Advertising
background image

4.2 Mounting instructions

OPTISWITCH 5100 C, 5150 C has a defined thread starting

point. This means that every OPTISWITCH 5100 C, 5150 C is

in the same fork position after being screwed in. Remove

therefore the supplied seal from the thread of OPTISWITCH

5100 C, 5150 C. This seal is not required when using a welded

socket with O-ring in front.
Keep in mind that this welded socket is not suitable for coated

instrument versions.
Screw OPTISWITCH 5100 C, 5150 C completely into the

welded socket. The later position can be determined already

before welding. Mark the appropriate position of the welded

socket. Before welding, unscrew OPTISWITCH 5100 C, 5150

C and remove the rubber ring from the welded socket. The

welded socket has a marking (notch). Weld the socket with the

notch facing upward, or in case of pipelines, aligned with the

direction of flow.

1

Fig. 7: Marking on the welded socket

1

Marking

In case of horizontal mounting in adhesive and viscous

products, the surfaces of the tuning fork should be vertical in

order to reduce buildup on the tuning fork. On the screwed

version you will find a marking on the hexagon. With this, you

can check the position of the tuning fork when screwing it in.

When the hexagon touches the seal, the thread can still be

turned by approx. half a turn. This is sufficient to reach the

recommended installation position.
With flange versions, the fork is directed to the flange holes.

Welded socket

Adhesive products

OPTISWITCH 5100 C, 5150 C - with NAMUR output

13

Mounting

30429

-EN

-060831