Signal converter M10-EEx d – Supplementary instructions

11/2002

4

2

Safety-relevant type code


The safety-relevant type code is made up of the following elements:

(1)

H .... / .... / M10 - E Ex

1 2 3 4 5

1 :

Model series : measuring section

H54

:

measuring section, Series H54

H250

:

measuring section, Series H250

H250C

:

measuring section, Series H250C

2 :

Material of wetted parts

RR

: stainless

steel

HC

: Hastelloy

Ti

: titanium

PTFE

: PTFE,

ceramics

3 :

Model series : indicator section

M10

:

signal converter M10

4 :

Territorial application of the approval

E:

Europe (EC, CENELEC area of validity)

5 :

Safety function

Ex:

explosion-protected electrical equipment

(1)

places for items not needed may be omitted from the type code

3

Main safety-relevant characteristics

The H..../..../M10-EEx variable-area flowmeter consists of a combination of signal converter and
measuring tube. The main characteristics of the explosion-protected version are described below.

3.1 Process

products

Flammable products are allowed provided they are not present in potentially explosive form.

3.2

Category / Zone allocation

The H..../..../M10-EEx variable-area flowmeter is basically designed in Category 2 for use in
Zone 1.

3.3

Type of protection

The H..../.

.../M10-EEx variable-area flowmeters bear the following marking: EEx d IIC T6

3.4 Special

lock

The sealing covers of the electronics compartment are secured by a special lock. The locking
screw requires use of an Allen key (3 mm size).