Installation – KROHNE OPTIFLEX 2200 IECEX User Manual

Page 14

Advertising
background image

2

INSTALLATION

14

OPTIFLEX 2200 C/F

www.krohne.com

04/2013 - 4000861902 - AD IECEX OPTIFLEX2200 R02 en

Compact version
EPL Gb: Ex ia and Ex d ia devices
EPL Gc: Ex ic devices

Temperature

class

Maximum ambient temperature

Max. flange

temperature

Ø2 mm / Ø0.08¨

single cable probe

(HT version)

Ø2 mm / Ø0.08¨

single cable probe

(other versions)

All other probe types

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

T6

+54

+129

+52

+125

+53

+127

+60

+140

+51

+124

+42

+107

+45

+113

+85

+185

T5

+69

+156

+67

+152

+68

+154

+75

+167

+66

+151

+57

+134

+60

+140

+100

+212

T4

+79

+174

+77

+170

+78

+176

+85

+185

+76

+169

+67

+152

+70

+158

+110

+230

+73

+163

+57

+134

+62

+143

+135

+275

T3

+71

+160

+51

+124

+57

1

+134

1

+150

+302

+68

+154

-

-

-

-

+180

2

+356

2

+65

+149

-

-

-

-

+200

2

+392

2

T2

+60

+140

-

-

-

-

+250

2

+482

2

+54

+129

-

-

-

-

+300

2

+572

2

1 If the device has an adaptor for BM 102 probes, this temperature is only permitted for devices that have an extension option
2 Make sure that gasket temperature is in the specified limits. For more data, refer to the handbook.

Temperature

class

Minimum ambient temperature

Min. flange

temperature

Ø2 mm / Ø0.08¨

single cable probe

(HT version)

Ø2 mm / Ø0.08¨

single cable probe

(other versions)

All other probe types

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

T6...T2

-40

-40

-40

-40

-40

-40

-40

1

-40

1

-39

-38

-36

-32

-37

-34

-50

1

-58

1

1 Make sure that gasket temperature is in the specified limits. For more data, refer to the handbook.