6.4 Description of functions
6.4.1 Reset counter in quick setup menu
6.4.2 Deleting error messages in the quick setup menu
INFORMATION!
It may be necessary to activate resetting of the counter in the Quick Setup menu.
Button
Display
Description and setting
>
quick setup
Press and hold for 2.5 s, then release the key.
>
language
2 x ↓
reset
>
reset errors
↓
counter 1
Select desired counter.
↓
counter 2
↓
counter 3
>
reset counter
no
↓ or ↑
reset counter
yes
^
counter 1,2
Counter has been reset.
3 x ^
Measuring mode
INFORMATION!
For the detailed list of the possible error messages refer to Status messages and diagnostic
information on page 70.
Key
Display
Description and setting
>
quick setup
Press and hold for 2.5 s, then
release the key.
>
language
2 x ↓
reset
>
reset errors
>
reset?
no
↓ or ↑
reset?
yes
^
reset errors
Error has been reset.
3 x ^
Measuring mode
.book Page 69 Friday, July 9, 2010 12:29 PM