KROHNE OPTISONIC 7060 EN User Manual

Page 33

Advertising
background image

OPTISONIC 7060

Electrical & mechanical installation manual 730962.31.00 page 33 of 52

Safety-relevant data of inputs and outputs

Output circuit

Intrinsically safe EEX ia IIA / IIB / IIC

Non-intrinsically
safe U

M

= 253 V

U

o

= 22.1 V

EEx ia IIA

EEx ia IIC

I

o

[mA]

P

o

[mW]

C

o

[nF]

L

o

[mH]

C

o

[nF]

L

o

[mH]

155 / 155

857 / 857

4100

7

163

1

Active current output
Terminals 31/32

Characteristic curve: linear
Internal capacity C

I

= 4 nF, internal inductance L

I

= 0.075 mH

Only for connection to passive, intrinsically safe circuits or intrinsically safe
circuits with the following maximum values: U

I

= 30 V

U

B

= 18 V

I

B

= 35 mA

Passive current
output
Terminals 31/32

U

I

= 30 V

I

I

= 100 mA

P

I

= 750 mW

C

I

= 4 nF

L

I

= 0.075 mH

U

B

= 30 V

I

B

= 35 mA

Digital output
Terminals 51/52,
41/42, 81/82

U

I

= 30 V

I

I

= 100 mA

P

I

= 750 mW

C

I

= 4 nF

L

I

= 0.075 mH

U

B

= 30 V

I

B

= 100 mA

RS 485
Terminals 81/82

Characteristic curve: linear
U

o

= 5.88 V

I

o

= 313 mA

P

o

= 460 mW

C

o

= 1000 µF/43 µF

L

o

= 1.5/0.2 mH


U

I

= 10 V

I

I

= 275 mA

P

I

= 1420 mW

U

B

= 5 V

I

B

= 175 mA

PROFIBUS PA
Terminals 33/34

U

I

= 30 V

I

I

= 100 mA

P

I

= 750 mW

EEx ia IIA

EEx ia IIB

EEx ia IIC

Ultrasonic
transducer
connections

Characteristic curve: linear
Max. transmission voltage U

o

= 60.8 V

Short-circuit current I

o

= 95 mA

P

o

= 1444 mW

C

o

= 300 nF

U

o

= 51.2 V

I

o

= 80 mA

P

o

= 1024 mW

C

o

= 187 nF

U

o

= 38.9 V

I

o

= 60 mA

P

o

= 584 mW

C

o

= 34 nF




Special

conditions


For connection to a NAMUR amplifier, the digital output (terminals, 51/52, 41/42,

81/82) can be wired internally as a NAMUR contact by setting a jumper (for details see

Service manual). Open Collector or NAMUR configuration is carried out at the factory in

accordance with the order details. If no configuration was specified in the purchase order,

the digital output is configured as Open Collector.

Digital output as Open Collector

Digital output in accordance with NAMUR



Fig. 3.10: Wiring digital outputs

Advertising