INSTALLATION

Page 2

Faster flow causes

meter to read high

FLOW

Distorted flow

profile

BEST

Okay, if no air in pipe

Okay, if no sediment in pipe.

Fitting Installation.

TX800-Series meters require special fit-

tings. The meter fitting must first be installed in the pipeline.

Straight pipe of at least ten times the diameter upstream of

the meter and five diameters downstream is strongly recom-

mended in order to achieve proper accuracy. These are

minimum values. As the diagrams on the the next page will

show, you may need more straight run under specific adverse

circumstances.

If you can’t provide enough run to smooth out the turbulence

caused by valves, fittings, and changes in direction, some

decrease in accuracy may result. This does not mean that

the flow meter’s reading is meaningless, however. In some

applications (for instance, where the flow meter is part of a

control system, operating a valve or controlling chemical ad-

dition), a repeatable reading may be more important than a

highly accurate one.

TX800-Series PVC meter tees are supplied with some

upstream straight pipe. The length provided may be less

than ten diameters upstream and five downstream. It

is not advisable to connect directly to the end of these

fittings with a flow-disturbing device such as a valve or

elbow. If possible, straight pipe should be added to the up-

stream end of these fittings.

A PVC fitting is usually installed by solvent welding. The stain-

less steel and brass meter fittings have female pipe threads,

requiring the appropriate male threaded fittings. Saddle fit-

Caution:

Never remove the u-clip retainer

when the pipe is under pressure. Always

remove pressure from the pipe before you

attempt to remove the meter. Removal un-

der pressure may result in damage or serious injury.

tings (size 3” and above) require a hole to be cut in the pipe.

The recommended hole size is 1-3/4”.

Meter Installation.

After the meter fitting is installed in the

pipeline, the meter can be installed in the fitting. Press the

meter into the fitting as far as it will go. Retain the meter in

place by inserting the u-pin. The pin can be installed from

either side. It may be necessary to rotate the probe back and

forth slightly to start the pin into the slots on the probe. Slide

the pin in as far as it will go.

DISTORTED FLOWS

POSITIONING THE METER

10X

Diameter Minimum

(See Below)