Problem

Probable Cause

Try...

Blank display

Flow rate steadily reads

zero when there is flow

Display reads [ - ]

Flow rate intermittently

drops when there is flow

Jumpy reading

Replace battery pack

Reading will resume when flow increases

Reposition meter for full pipe

Note flow direction arrow, reverse meter

Reposition meter for full pipe or rotate to avoid

bubbles

Check for proper equalization

Use external power source

(allows more flow averaging)

Install chemigation line downstream of meter

(or enough upstream for thorough mixing of

fluids before meter)

Dead battery

Flow is below cutoff (very low)

There is air in the meter

Meter is installed backward

There is air in the meter

Improperly equalized

Pulsing flow

Rapidly changing conductivity

(chemigation applications)

TROUBLESHOOTING

Not Currently Assigned

for Use.

External Power

Pulse Output

AG2000 Cable

Blue
Orange

Black (-)
Red (+)

Shielded

Direct Burial Cable

22 AWG Stranded

White (-)
Green (+)

Drain Wire

Optional Input/Output Cable

Factory or Field Installed

FLOW

800.975.8153

Orange and Blue

: Serial Output (Technician Use Only)

Green (+) and White (-)

: Pulse Output, 30 Vdc max, 10 mA max

Red (+) and Black (-)

: External Power, 8-32 Vdc at 30 mA max

Drain

: Connect to earth ground (See WARNING)

WARNING:

Using an unregulated power

supply >18 Vdc may damage the meter

due to AC line input voltage fluctuation.

Optional Input and Outputs

. An optional cable, factory-

installed or field-installed by an authorized individual, provides

power input, pulse output* for remote reading (4-20 mA

conversion, telemetry and data logging functions). See diagram

below. Detailed wiring diagrams provided with cable.

IMPORTANT:

When field installing the input/output cable, be

sure to snugly tighten the cable strain relief to prevent water

ingress.

*See High Frequency Output Technical Bulletin for available

pulse rates.

For data logger setup and operation refer to FlowInspector manual.

OPTIONAL INPUTS, OUTPUTS and TROUBLESHOOTING