Seametrics AG1000 User Manual

Page 4

Advertising
background image

Page 2

INSTAllATION AND ElECTRICAl CONNECTIONS

Caution: These flow sensors are not

recommended for installation where

temperature exceeds 120°F.

Positioning the Meter. These are all-position meters,

meaning that they can be installed horizontally, vertically,

and in any radial position. If there is potentially a problem

with sludge accumulation, vertical or horizontal with the

register up may be preferred. See recommendations on

pages 3 and 4.

Piping Conditions. As with most flow meters, the AG1000

requires some straight pipe before and/or after the meter for

best accuracy. However, the tendency of electromagnetic

meters to average the flow across the entire pipe allows

for shorter straight pipe recommendations than most

mechanical meters. Follow the guidelines on page 3 for

the type of installation that best matches yours.

Although the meter is designed with an empty pipe

detection feature, it requires that one or more electrodes

be exposed. An installation in which the pipe is nearly but

not quite full will cause reading errors. Be sure that the

piping is configured to ensure that the pipe is full when

there is flow. See diagrams on page 4 for examples of

recommended installations.

The AG1000 is available with either grooved or flanged

ends. Flanges have standard ANSI 150 lb drilling, and

should match up with any other ANSI 150 lb flange.

Electrical Connections. A current source of some kind at

12 to 24 VDC must be connected to the meter. If needed for

remote reading, logging or telemetry, the pulse output can

also be connected. See the Connections diagram on page

5 for guidance. It shows the color coding of the pre-installed

power/pulse output cable. If it is necessary to replace this

cable, for instance to install a longer one, see the drawings

for proper installation of the cable into the connector.

Electrical Noise Immunity. For best results, connect

grounds and cable shielding as shown in the diagram on

page 5, and install the included ferrite beads by snapping

them onto the outside of the cable.

INSTAllATION

ElECTRICAl CONNECTION

Caution: There are no connections inside

the display. Breaking the seal wire will

VOID WARRANTY.

Advertising