Repair

The only field-repairable component on the FT520 is the
fuse. If failure is due to a cause other than a blown fuse,
it is necessary to replace the entire board stack. Contact
your distributor for information.

Fuses. The power supply and the analog output circuit
have fuse protection. The two fuses are on the board.
Replace the blown power fuse with a 250 mA, 5x20 mm
glass fuse, available from SeaMetrics or from Radio
Shack (or other electronic supply store). The DC power
fuse is a 1 Amp, 5x20 mm glass fuse.

4 of 4

20419 80th Ave. So., Kent WA. 98032 USA

Phone: 253-872-0284 Fax: 253-872-0285

www.seametrics.com 1-800-975-8153

Caution: Always disconnect
power to the unit before open-
ing the terminal cover. Do not
reconnect power until all con-
nections have been made and
the terminal cover has been re-
placed.

5.50"

gasket

PANEL
CUTOUT

5.50"

6.03"

6.03"

1/4" holes (4 required)