20
Memory function
4.5
Each setting value can be saved and read out.
Saving each setting value
4.5.1
This function is used to save each setting value.
There are two types of saving methods, one is to save a parameter by pressing and holding the
“LOAD(SAVE)” key, and the other is to save a setting value by turning the power OFF.
The number of data entries that can be set is five on internal oscillation emission and external
synchronous emission respectively when saving by the “LOAD(SAVE)” key, and one when saving
by power OFF.
Setting values that can be saved
Saving method
Save a parameter using the
“LOAD(SAVE)” key
Save when the power is turned OFF
Emission status when the value is saved
Internal
oscillation
emission
External
synchronous
emission
Internal
oscillation
emission
External
synchronous
emission
Memory number that can be saved
1 to 5
1 to 5
-
-
Emission mode (INT/EXT)
Ч
Ч
○
○
Setting mode (FPM/DUR/PHASE)
○
○
○
○
Internal
oscillation
emission
(INT)
Emission frequency (FPM)
○
×
○
○
Emission duration (DUR)
○
×
○
○
Delay angle (PHASE)
○
×
○
○
Delay time (PHASE)
○
×
○
○
External
synchronous
emission
(EXT)
Emission duration (DUR)
×
○
○
○
Delay angle (PHASE)
×
○
○
○
Delay time (PHASE)
Ч
○
○
○