SHIMPO DEG-2000 User Manual
Page 27
25
7.3.7 Two-item judgment result output –– Output signal arrangement
The two-item judgment result output signal is output when “ITEM 1&2” is selected with
[JUDG OUT] in the set mode (6).
Note:
“Item” refers to “ITEM” of DEG2000. The following table shows the output
signal arrangement of the DC input/output connector (refer to ◯
15
on page
7).
Pin No.
Signal name
Description
11
READY
Turns on in measure mode during normal operation.
12
Error
Turns on when two signals are simultaneously input and
turns off when all signals are turned off.
13
Master OK
Turns on when mastering result is OK.
14
Check input signal
Turns on when input signal is received and processing is
completed, and turns off when input signal is turned off.
15
All OK
Turns on at input of measure command when all items
are OK.
16
All NG
Turns on at input of measure command when any one
item is NG.
17
Item 1 -NG
18
+NG
19
OK1
20
OK2
21
OK3
22
OK4
23
OK5
24
OK6
25
OK7
26
Item 2 -NG
27
+NG
28
OK1
29
OK2
30
OK3
31
OK4
32
OK5
33
OK6
34
OK7
35
-COM
36
-COM
Output common line: 0 V