Installation . . .

Install AFS models in piping system using standard pipe fitting procedures. Be
sure to keep thread sealing compound out of unit. Install so that flow is in proper
direction (marked "IN" and "OUT" on housing). Use of 50 micron filtration is
recommended.

Piston-Type Flow Switches

AFS Series

Electrical Data . . .

Typical Wiring Diagram . . .

3-Pin Receptacle

Amps AC

.4

.17
.08

Amps DC

.3

.13
.06

Volts

0-30

120
240

VA

Switch Ratings - Max Resistive Load

20

*

Minimum line pressure for positive actuation.

15% Max.

Housing

Piston

(In Brass Housing)

Piston (SS Housing)

Other Wetted Parts

Operating

Proof

Burst

With SS or Brass Piston

With Polysulfone Piston

For 5 PSIG Line

*

For 100 PSIG Line

Materials

Liquid Flow Adjustable Range - Water

Pressure

Ratings

Operating

Temperatures

-20

o

to +300

o

F(-29

o

C to +148.9

o

C)

-20

o

to +225

o

F(-29

o

C to +107.2

o

C)

Repeatability

1% Max. Deviation

Set Point Differential

Set Point Accuracy (Constant Temperature)

Factory-Set (Standard)

±10% Max.

Switch (See Electrical Data, Below)

SPDT, 20 VA

Lead Wires

No. 18 AWG, 24" L., Polymeric

Specifications . . .

Air/Gas Flow Adj. Ranges:

(Dep. on Oper. Line Pressure)

Note: Temperature changes will slightly affect water or gas flow settings.
Oil settings will vary with viscosity.

Brass or 316 SS

Polysulfone for Water

Brass for Oil or Air

316 SS

316 SS, Viton, Epoxy

0.5 to 20 GPM

1000 PSIG

2500 PSIG

5000 PSIG

For 100 PSIG Line: 3 to 160 SCFM Approx.

For 5 PSIG Line

*

: 1 to 75 SCFM (Approx.)

A

C

Red

Black

Orange

B

DWYER INSTRUMENTS,INC.

P.O.BOX 373 MICHIGAN CITY, INDIANA 46361, U.S.A.

Phone: 219/879-8000
Fax: 219/872-9057
Lit-By Fax: 888/891-4963
www.dwyer-inst.com
e-mail: [email protected]

Important Points!

Product must be maintained and installed in strict accordance
with the National Electrical Code and Dwyer product catalog
and instruction bulletin. Failure to observe this warning could
result in serious injuries or damages.

For hazardous area applications involving such things as (but
not limited to) ignitable mixtures, combustible dust and
flammable materials, use an appropriate explosion-proof
enclosure or intrinsically safe interface device.

The pressure and temperature limitations shown on the
individual catalog pages and drawings for the specified flow
switches must not be exceeded. These pressures and
temperatures take into consideration possible system surge
pressures/temperatures and their frequencies.

Selection of materials for compatibility with the media is critical
to the life and operation of Dwyer products. Take care in the
proper selection of materials of construction, particularly wetted
materials.

Life expectancy of switch contacts varies with applications.
Contact Dwyer if life cycle testing is required.

Ambient temperature changes do affect switch set points,
since the specific gravity of a liquid can vary with temperature.

Dwyer Products have been designed to resist shock and
vibration; however, shock and vibration should be minimized.

Filter liquid media containing particulate and/or debris to
ensure the proper operation of our products.

Electrical entries and mounting points in an enclosed tank
may require liquid/vapor sealing.

Dwyer Products must not be field-repaired.

Physical damage sustained by the product may render it
unserviceable.