ACTiSYS ACT IR100SLM User Manual

Page 11

Advertising
background image

- 10 -

ACT-IR100SL and IR100SL-M User’s Manual

Version 1.20

May 27, 2002

4.2 Baud Rate Setting

Jumpers SEL0-2 and serial EPROM settings are used to set the host interface RXD and TXD data

rate. Note that this is independent of the IrDA connection data rate.

Data format is always 8 data bits, no parity, and 1 stop bit. Note that this is compatible with

end-to-end data format using 7 data bits, parity, and 1 stop bit. That is, the application at both end

of the IrDA link may generate and check parity if 7 data bit is used.

The Host Interface can operate on eight different baud rates from 1.2kbps to 115.2kbps.

Jumpers

Baud Rate

SEL2

SEL1

SEL0

1.2kbps

0 0 0

2.4kbps

0 0 1

4.8kbps

0 1 0

9.6kbps

0 1 1

19.2kbps

1 0 0

38.4kbps

1 0 1

57.6kbps

1 1 0

115.2kbps

1 1 1

SEL7 ~ SEL0 (D12 ~ D5):

1: None

0: Install DIODE (1N4148)

PCB bottom view

SEL

0

SEL

1

SEL

2

SEL

3

SEL4

SEL5

SEL6

SEL7