MXL V67N User Manual

V67n, V67n specs, Small diaphragm instrument microphone

Advertising
background image

Warranty

Marshall microphones are guaranteed against defects in material and workmanship for three years from date of purchase. Should you encounter any

problem with this unit, promptly contact the company you purchased it from for assistance. The original dated sales receipt will be necessary for any

warranty claim. Do not send any unit directly to us without prior authorization from our service department! Warranty coverage is limited to repair or

replacement (at our option) of the microphone, and does not cover incidental damages due to use of this unit, nor damage caused by accidental
misuse of this product.

Type:

Pressure gradient condenser microphone

Diaphragm:

22mm Gold-sputtered, 6 micron

Frequency Range:

20 Hz – 20 kHz

Polar Pattern:

Cardioid/Omni

Sensitivity:

-49dB re 1 V/Pa

Impedance:

<300 ohms

S/N Ratio:

78dB

Equivalent Noise Level:

-16dBA (A weighted IEC 651)

Max SPL for 0.5% THD:

148dB SPL

Current Consumption:

5.2mA

Power Requirements:

48V Phantom Power (+/- 4V)

Size:

124mm x 23mm

Weight:

0.2 lbs

Metal Finish:

Green with gold grill

V67N Specs:

Marshall Electronics, Inc.

1910 East Maple Ave. El Segundo, CA 90245

Phone: (310) 333-0606 Fax: (310) 333-0688

E-mail: [email protected]

Internet: www.MXLmics.com

Frequency Response

Small Diaphragm

Instrument Microphone

Thank you for purchasing the MXL V67N Small Diaphragm Instrument Microphone. MXL

microphones

are the result of world-class engineering and manufacturing capabilities. Our products are designed to

provide you with outstanding performance and exceptional value. For the best results, please take a few

moments to review this literature.

General Characteristics

This microphone includes two interchangeable capsules with gold-sputtered diaphragms. One capsule is designed

for a cardioid pick-up pattern; the other capsule is designed for an omni-directional pickup pattern. Condenser

microphones are very sensitive, readily revealing very subtle sonic details. They also tend to pick up sounds outside

the pattern more than some designs, which can lead to powerful feedback if you are not careful. We strongly advise

experimentation with placement and isolation requirements with the gain initially set low to avoid equipment

(and ear) damage.

Power Requirements

IMPORTANT -

This microphone requires phantom power at 48 volts, +/- 4 volts. This unit has been thoroughly

checked before shipping, so if you do not hear sound, check that the phantom power on your mixer, preamp, or

separate power supply is switched on.

Microphone Cables

The microphone cable can have a profound effect on the sound of any microphone. Even the finest microphones will

sound poor if the interconnect cable allows noise to enter or causes distortion and loss of information. Use only the

best microphone cable your budget will allow. We highly recommend using Mogami

®

brand cable.

Care

Dust and foreign material can degrade the performance of a microphone over time so always store the unit in its box.

For more information about MXL microphones, visit mxlmics.com

0

90

270

180

Cardioid

Omni

Polar Pattern

V67N