Sterlco 140 to 6,285 Gallon Pump Tanks User Manual
Page 3
Pump Tanks
iii
Table of Contents
CHAPTER 1:
SAFETY ................................................................ 5
1-1 How to Use This Manual ................................................................................... 5
Safety Symbols Used in this Manual ..................................................................... 5
1-2
Warnings and Precautions ................................................................................ 6
1-3
Responsibility .................................................................................................... 6
CHAPTER 2:
FUNCTIONAL DESCRIPTION ............................. 7
2-1
Models Covered in This Manual ....................................................................... 7
2-2
General Description .......................................................................................... 7
2-3
Standard Features ............................................................................................ 8
2-4
Optional Features ............................................................................................. 9
CHAPTER 3:
INSTALLATION ................................................. 10
3-1
Uncrating Your Pump Tank ............................................................................. 10
3-2
Installation Location Considerations ............................................................... 10
3-3
Rigging ............................................................................................................ 10
3-4
Installing Separate Tank Ledge Models .......................................................... 11
3-5
Installing Optional Equipment ......................................................................... 11
3-6
Making Electrical Connections ........................................................................ 11
3-7
Making Piping Connections ............................................................................ 12
Tower Tank Piping Connections ......................................................................... 14
Chilled Water Piping Connections ....................................................................... 15
3-8 Initial Start-up .................................................................................................. 15
CHAPTER 4:
OPERATION ....................................................... 16
4-1
Start-up ........................................................................................................... 16
4-2
Determining Flow Rate .................................................................................... 16
4-3
Stand-by Pump Usage .................................................................................... 17
Single Stand-by pump: ........................................................................................ 17
Dual Stand-By Pump ........................................................................................... 17
4-4
Shut-down ....................................................................................................... 17
4-5
Display ............................................................................................................ 17
4-1
Alarm History .................................................................................................. 26
4-2
Setup ............................................................................................................... 26
4-3
Manual Mode .................................................................................................. 32
4-4
Hour Meters .................................................................................................... 33
4-5
Options – Analog Inputs .................................................................................. 33
4-6
Options – Analog Outputs ............................................................................... 34
4-7
Options – Digital Inputs ................................................................................... 34
4-8
Options – Digital Outputs ................................................................................ 35
4-9
Process Pump Control .................................................................................... 36
4-10
Recirc. Pump control ...................................................................................... 36
4-11
Standby Pump Control ................................................................................... 37
4-12
Tower Fan Control ......................................................................................... 37
4-13
Alarms ............................................................................................................ 38
CHAPTER 5:
MAINTENANCE ................................................. 49
5-1 Preventative Maintenance .............................................................................. 49
Water Treatment ................................................................................................. 49