Ultravation UMX EZUV Signature Series- DC-OH-0229 User Manual

Signature series, Homeowner / user guide, Ultramax

Advertising
background image

1-866-GO-UV-AIR (468-8247)

ultravation.com

DC-OH-0229A

SS-2412-EZ
SS-2419-EZ

Signature Series

Homeowner / User Guide

Thank you for purchasing an Ultravation

®

Professional Indoor Air Quality Product

UltraMAX

EZUV

Signature Series

UV Air and Surface Disinfection for HVAC

LED

Audible Alarm

Unit Status

Blue

No Sound

Normal

Flashing Red

6 second beep

Replace Lamp(s)

Your UltraMAX™ EZUV™ is equipped

with an electronic power supply that

monitors operation and protects the UV

lamp filaments. It also monitors elapsed

time and reminds after 18,000 hours of

operation that lamps need to be replaced.

Below is a chart that describes how to

interpret the display.

UVLampMonitor Status

To silence alarm, press reset for one second.

Package Contents:

• Light Shield

• T3 Enhanced UVC Light

• ESP3 24VAC Power Supply with

power switch and diagnostics

• Magnetic Mount

• 6 - 3/4 inch 5/16 self tapping sheet

metal screws

• Warranty Card

UL Listed. The health aspects associated with the use of this product and its ability to aid in disinfection of environmental
air have not been investigated by UL.

SAFETY PRECAUTIONS:

It is recommended that this unit be installed and maintained by a trained technician:

WARNING: UV Hazard. Always protect eyes from ultraviolet light.
NEVER look at UV lamps in operation. Unplug or disconnect power before
re-lamping or servicing.

WARNING: Severe eye damage or temporary blinding may occur.

WARNING: DO NOT operate outside of air handler. Mount lamp base to
duct first.

WARNING: No openings in HVAC system are allowed which would give
direct line-of-sight to the UV light.

In the event of accidental breakage or replacement of the ultraviolet lamp, please
ensure that the lamp is disposed of in accordance with local and state environmental
laws regarding fluorescent lamps containing mercury.

Notice: All wiring inside air handling system in direct line of site of the UV lamp must
be shielded with aluminum foil tape or equivalent non-combustible material. When
installing this unit, select a mounting location that prevents ultraviolet light exposure
to plastic non UV-rated flexible duct liner or other plastic components with unknown
resistance to ultraviolet light. Ultraviolet light may cause color shift or structural
degradation of plastic HVAC components. If installing where UV light can directly
contact fiberglass duct board, contact manufacturer of fiberglass product for advice
on UV rating. If unknown, install metal sheathing or foil tape to completely protect
fiberglass duct board from UV light exposure.

Lamp Replacement and Reset Procedure

It is recommended that a certified technician perform these operations.

Note to technician: When replacing lamps, turn off power to the unit first. Then

follow installation instructions for lamp replacement.

After the lamps are in place, the Service Indicator Light must be reset.

Steps for resetting the Service Indicator Light

1. Restore power to the EZUV Signature Series unit and turn it on.

2. Press down and hold the RESET button for 10 seconds. The LED will turn blue

while button is depressed.

3. Release the RESET button.

4. The LED should remain blue after button is released.

REPLACEMENT PARTS AND ACCESSORIES

12" T3 UVC Lamp ..............................................................................

AS-IH-1001

17" T3 UVC Lamp ..............................................................................

AS-IH-1003

12” Light Shield with magnet .............................................................

94-066-M

17” Light Shield with magnet ..............................................................

94-067-M

Optional PCO plate ............................................................................

94-004

Please contact your local dealer or use the Authorized Contractor Locator on

Ultravation.com for replacement lamps and parts.

Troubleshooting

Ultravation® air disinfection equipment is designed to provide many years of trouble
free operation. In the unlikely event of a problem, please contact your local HVAC
professional or Ultravation directly. Before calling for service, you should have the
model number, serial number, and purchase date.

If you are troubleshooting the unit, please check the following:

• To save energy and maintain performance, the EZUV Signature Series automatically

turns off if the lamp has not been changed after two years. If this is the case,

replace the lamp and press the reset button on the side of the power supply.

• Verify that the UV lamp(s) is on or off—but never look at a UV lamp in operation!

You can safely confirm operation by way of the UV viewport installed with the unit.

• Verify the unit has power. Check voltage requirement on power supply label and

confirm proper power is supplied.

• Be sure lamps are securely plugged into their sockets, no loose wires, and in the

correct orientation (see other side of this sheet).

• If possible install a new lamp to determine whether the problem is the lamp or the

power supply.

Remember: DO NOT look at UV light without proper eye protection.

Lifetime Warranty

Ultravation® EZUV™ Signature Series features Ultravation’s lifetime warranty, with the
exception of the ultraviolet lamp(s), which are warranted for a period of one year after
date of consumer purchase.

This warranty does not include damage to the unit from accident, misuse or improper
installation.

If this product should become defective, Ultravation will elect to repair or replace the
product free of charge. Ultravation will return repaired or replaced warranted products
pre-paid to the customer, provided that the product was delivered pre-paid.

Ultravation shall have no responsibilities for charges incurred by the customer for
installation or removal of warranted items. Liability is limited only to the replacement or
repair of this product.

This warranty gives you specific legal rights, and you may also have other rights, which
vary from state to state. All returns must be accompanied by a return authorization
number, which may be obtained by contacting Ultravation, Inc.

Ultravation, Inc.

P.O. Box 165, 212 Ideal Way, Poultney, Vermont 05764
Phone: 1-866-GO-UV-AIR (468-8247) • Fax: 802-287-9203
www.ultravation.com • [email protected]

Copyright © 2008-2013 Ultravation Inc.

Ultravation.com

Advertising