Comfort cool installation manual - l1_ 6, Installation site instruction – Electrolux EXI12HD1WE User Manual
Page 6
6
Installation Site Instruction
More than 30cm
More than 30cm
More than 2m
More than 50cm
More than 15cm (ceiling)
More than
15cm
More than
15cm
0RUHWKDQPÀRRU
/HVVWKDQPÀRRU
7 Select place about 1m or more away from a
TV set or any other electric appliance.
8
6HOHFWDSODFHZKHUHWKH¿OWHUFDQEHHDVLO\
taken out.
9 Do not use the unit in the laundry or by
swimming pool etc.
10 A minimum pipe run of 3 meters is required to
minimize vibration and noise.
11
8VHDVWXG¿QGHUWRORFDWHVWXGVWRSUHYHQW
unnecessary damage to the wall.
12 Any variations in pipe length will/may require
adjustment to refrigerant charge.
13 Do not install near a door way.
Outoor Unit
1
6HOHFWDVLWHZKHUHQRLVHDQGRXWÀRZDLU
emitted by unit will not annoy neighbors.
2
6HOHFWDVLWHZKHUHWKHUHLVVXI¿FLHQW
ventilation.
3 Select a site where there is no obstruction
blocking the inlet and outlet.
4 The site should be able to withstand the full
weight and vibration of the unit.
5
6HOHFWDGU\SODFHEXWGRQRWH[SRVHWKHXQLW
to direct sunlight or strong wind.
6 Make sure that the outdoor unit is installed in
accordance with the installation instructions,
and is convenient for maintenance and repair.
7 Select a place where it is out of reach of
children and far from animals or plants.
8 Select a place where the unit keeps the
horizontal and aligned position.
9 Select at a place that respects the minimum
distances around the outdoor unit as below:
A proper installation site is vital for correct and
HI¿FLHQWRSHUDWLRQRIWKHXQLW
Avoid the following sites where:
VWURQJKHDWVRXUFHVYDSRXUÀDPPDEOHJDV
or volatile liquids are emitted.
high-frequency electro-magnetic waves are
generated by radio equipment, welders or
medical equipment.
salt-laden air prevails (such as close to
coastal areas).
the air is contaminated with industrial vapours
and oils.
the air contains sulphurous gas such as in hot
spring zones.
FRUURVLRQRUSRRUDLUTXDOLW\H[LVWV
Indoor Unit
1 The air inlet and outlet should be away from
the obstructions. Ensure the air can be blown
through the whole room.
2 Select a site where the condensing water can
be easily drained out, and where it is easily
connected for the outdoor unit.
3 Select a place where it is out of reach of
children.
4 Select the place where the wall is strong
enough to withstand the full weight and
vibration of the unit.
5 Be sure to leave enough space to allow
access for routine maintenance.
For optimum performance, the indoor unit
should be installed on the wall at a height
PHWHUVRUPRUHDERYHWKHÀRRUEXWOHVV
WKDQPHWHUVIURPWKHÀRRU
6 Make sure that the indoor unit is installed in
accordance with installation dimension as
below: