Installation Site Instruction

More than 30cm

More than 30cm

More than 2m

More than 50cm

More than 15cm (ceiling)

More than
15cm

More than
15cm

0RUHWKDQP ÀRRU 
/HVVWKDQP ÀRRU 

7 Select place about 1m or more away from a

TV set or any other electric appliance.

8

6HOHFWDSODFHZKHUHWKH¿OWHUFDQEHHDVLO\
taken out.

9 Do not use the unit in the laundry or by

swimming pool etc.

10 A minimum pipe run of 3 meters is required to

minimize vibration and noise.

11

8VHDVWXG¿QGHUWRORFDWHVWXGVWRSUHYHQW
unnecessary damage to the wall.

12 Any variations in pipe length will/may require

adjustment to refrigerant charge.

13 Do not install near a door way.

Outoor Unit

1

6HOHFWDVLWHZKHUHQRLVHDQGRXWÀRZDLU
emitted by unit will not annoy neighbors.

2

6HOHFWDVLWHZKHUHWKHUHLVVXI¿FLHQW
ventilation.

3 Select a site where there is no obstruction

blocking the inlet and outlet.

4 The site should be able to withstand the full

weight and vibration of the unit.

5

6HOHFWDGU\SODFHEXWGRQRWH[SRVHWKHXQLW
to direct sunlight or strong wind.

6 Make sure that the outdoor unit is installed in

accordance with the installation instructions,
and is convenient for maintenance and repair.

7 Select a place where it is out of reach of

children and far from animals or plants.

8 Select a place where the unit keeps the

horizontal and aligned position.

9 Select at a place that respects the minimum

distances around the outdoor unit as below:

A proper installation site is vital for correct and
HI¿FLHQWRSHUDWLRQRIWKHXQLW

Avoid the following sites where:

‡ VWURQJKHDWVRXUFHVYDSRXUÀDPPDEOHJDV

or volatile liquids are emitted.

‡ high-frequency electro-magnetic waves are

generated by radio equipment, welders or
medical equipment.

‡ salt-laden air prevails (such as close to

coastal areas).

‡ the air is contaminated with industrial vapours

and oils.

‡ the air contains sulphurous gas such as in hot

spring zones.

‡ FRUURVLRQRUSRRUDLUTXDOLW\H[LVWV

Indoor Unit

1 The air inlet and outlet should be away from

the obstructions. Ensure the air can be blown
through the whole room.

2 Select a site where the condensing water can

be easily drained out, and where it is easily
connected for the outdoor unit.

3 Select a place where it is out of reach of

children.

4 Select the place where the wall is strong

enough to withstand the full weight and
vibration of the unit.

5 Be sure to leave enough space to allow

access for routine maintenance.

For optimum performance, the indoor unit
should be installed on the wall at a height
PHWHUVRUPRUHDERYHWKHÀRRUEXWOHVV
WKDQPHWHUVIURPWKHÀRRU

6 Make sure that the indoor unit is installed in

accordance with installation dimension as
below:

Advertising