Electrical connection, Connecting to the water supply, Making the appliance level – AEG LAVAMAT 50212 User Manual
Page 30: Permitted water pressure, Water inlet
30
Making the appliance level
The four feet of the appliance are
pre-adjusted.
Large degrees of unevenness can be
compensated for by individually ad-
justing the height adjustable screw
feet.
Use the special spanner supplied to
do this.
Important! Do not use pieces of
wood, cardboard or such like to lev-
el out unevenness in the floor, but
adjust the height adjustable screw
feet instead.
Electrical connection
Details about the voltage, type of supply and the fuses required are to
be found on the rating plate. The rating plate is next to the doorway.
Connecting to the water supply
Permitted water pressure
The water pressure must be at least 1bar (=10N/cm
2
=0.1MPa) and may
be a maximum of 10bar (=100N/cm
2
=1MPa).
– If more than 10bar: Connect a pressure reduction valve.
– If less than 1bar: Disconnect the appliance end of the inlet hose from
the solenoid inlet valve and remove the flow meter. (In addition re-
move the filter using pointed pliers and take out the rubber gasket
behind it.) Re-insert the filter.
Water inlet
Attention!
• An inlet hose is supplied and can be found inside the machine drum.
• Do not use the hose from your previous machine to connect to
the water supply.
• This appliance must be connected to a cold water supply.