Warning, Installation location requirements, Clearances – LG DLEX3070R User Manual

Page 13: English

Advertising
background image

13

ENGLISH

INSTALLATION INSTRUCTIONS

Installation location requirements

w

WARNINg

Read all installation instructions completely before installing and operating your dryer! It is important that you review this entire

manual before installing and using your dryer. Detailed instructions concerning electrical connections, gas connections, and exhaust

requirements are provided on the following pages.

Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic

cycle. This can result in longer drying times. The dryer must not be installed or stored in an area where it will be exposed to water and/or

weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or

sleeping quarters. Contact your local building inspector.

Clearances

InstallatIon spacIng for recessed area or closet InstallatIon

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0 inches (0 cm) clearance on

the sides and rear. Recommended spacing should be considered for the following reasons:

• A location that allows for proper exhaust installation. A gas dryer

must be exhausted to the outdoors. See Venting the dryer.

• A grounded electrical outlet located within 2 ft. (61 cm) of either

side of the dryer. See Connecting electric dryers.

• A sturdy floor to support the total dryer weight of 200 lbs (90.7

kg). The combined weight of a companion appliance should also

be considered.

• No other fuel-burning appliance can be installed in the same area

as a dryer.

• Additional spacing should be considered for ease of installation

and servicing.

• Additional clearances might be required for wall, door and floor

moldings.

• Additional spacing should be considered on all sides of the dryer

to reduce noise transfer.

For closet installation with a door, minimum ventilation openings

in the top and bottom of the door are required. Louvered doors

with equivalent ventilation openings are acceptable.

• Companion appliance spacing should also be considered.

24 in.

2*

(155 cm

2

)

18" min.*

(45.7 cm)

1"*

(2.5 cm)

30"

(76.1 cm)

30"

(76.1 cm)

5"**

(12.7 cm)

48 in.

2*

(310 cm

2

)

14" max.*

(35.6 cm)

3"

*

(7.6 cm)

3"

*

(7.6 cm)

1"

(2.5 cm)

27"

(68.6 cm)

1"

(2.5 cm)

1"*

(2.5 cm)

5"**

(12.7 cm)

14" max.*

(35.6 cm)

18" min.*

(45.7 cm)

0"

(0 cm)

39"

(99.1 cm)

1"

(2.5 cm)

27"

(68.6 cm)

1"

(2.5 cm)

30"

(76.1 cm)

5"**

(12.7 cm)

1"**

(2.5 cm)

1"

(2.5 cm)

1"

(2.5 cm)

27"

(68.6 cm)

9"**

(22.9 cm)

7"* (17.8 cm)

7"* (17.8 cm)

1"* (2.5 cm)

5 "**

(14 cm)

1/2

77

1/2

"

(196.8 cm)

Requisitos

deventilación de

lapuerta del armario

24 in.

2*

(155 cm

2

)

48 in.

2*

(310 cm

2

)

1"*

(2,5 cm)

5"**

(12,7 cm)

14" max.*

(35,6 cm)

3"

*

(7,6 cm)

3"

*

(7,6 cm)

1"

(2,5 cm)

27"

(68,6 cm)

1"

(2,5 cm)

1"*

(2,5 cm)

5"**

(12,7 cm)

14" max.*

(35,6 cm)

18" min.*

(45,7 cm)

0"

(0 cm)

39" min.

(99,1 cm)

1"

(2,5 cm)

27"

(68,6 cm)

1"

(2,5 cm)

18" min.*

(45,7 cm)

30"

(76,1 cm)

30"

(76,1 cm)

30"

(76,1 cm)

5"**

(12,7 cm)

1"**

(2,5 cm)

1"

(2,5 cm)

1"

(2,5 cm)

27"

(68,6 cm)

9"**

(22,9 cm)

7"* (17,8 cm)

7"* (17,8 cm)

1"* (2,5 cm)

5 "**

(14 cm)

1/2

77

1/2

"

(196,8 cm)

3"* (7,6 cm)

6"* (15,2 cm)

3"* (7,6 cm)

27"

(68,6 cm)

1"

(2,5 cm)

1"

(2,5 cm)

24 in.

2*

(155 cm

2

)

48 in.

2*

(310 cm

2

)

24 in.

2*

(155 cm

2

)

18" min.*

(45,7 cm)

1"*

(2,5 cm)

30"

(76,1 cm)

30"

(76,1 cm)

5"**

(12,7 cm)

48 in.

2*

(310 cm

2

)

14" max.*

(35,6 cm)

3"

*

(7,6 cm)

3"

*

(7,6 cm)

1"

(2,5 cm)

27"

(68,6 cm)

1"

(2,5 cm)

1"*

(2,5 cm)

5"**

(12,7 cm)

14" max.*

(35,6 cm)

18" min.*

(45,7 cm)

0"

(0 cm)

39"

(99,1 cm)

1"

(2,5 cm)

27"

(68,6 cm)

1"

(2,5 cm)

30"

(76,1 cm)

5"**

(12,7 cm)

1"**

(2,5 cm)

1"

(2,5 cm)

1"

(2,5 cm)

27"

(68,6 cm)

9"**

(22,9 cm)

7"* (17,8 cm)

7"* (17,8 cm)

1"* (2,5 cm)

5 "**

(14 cm)

1/2

77

1/2

"

(196,8 cm)

3"* (7,6 cm)

6"* (15,2 cm)

3"* (7,6 cm)

27"

(68,6 cm)

1"

(2,5 cm)

1"

(2,5 cm)

24 in.

2*

(155 cm

2

)

48 in.

2*

(310 cm

2

)

NOTE

There should be at least a little space around the dryer (or any other appliance) to eliminate the transfer of vibration from one to the

other. Too much vibration, it could cause them to make noise or touch each other causing paint damage and making even more

noise.

NOTE

• A level floor with a maximum slope of 1 inch (2.5 cm) under entire dryer. Clothes may not tumble properly, and automatic sensor

cycles may not operate correctly if dryer is not level.

• For a garage installation, you will need to place the dryer at least 18 inches (46 cm) above the floor. If using a pedestal, you will need

18 inches (46 cm) to the bottom of the dryer.

MFL62512860_en_111221.indd 13

2011.12.21 9:46:41 AM

Advertising