HP ProLiant DL380 Server User Manual

Page 31

Advertising
background image

CONREP -s (Store to Data file) Example usage for HP ProLiant 100 series servers

To extract the BIOS settings from an SL160z G6 server and save the configuration to an
"sl160zconrep.dat" data file:

[root@ilo002481b08134 conrep]# ./conrep -s -xconrepSL160zg6_20090728.xml -fsl160zconrep.dat

conrep 3.00 - Scripting Toolkit Configuration Replication Program

Copyright (c) 2007-2012 Hewlett-Packard Development Company, L.P.

System Type: ProLiant SL160z G6

ROM Date : 07/28/2009

ROM Family : O33

Processor Manufacturer : Intel

XML System Configuration : conrep_SL160zg6_20090728.xml

Hardware Configuration : sl160zconrep.dat

Saving configuration data to sl160zconrep.dat.

CONREP Return code: 0

NOTE:

The file names after the -x and -f options must be specified, otherwise, the default file

names conrep.xml and conrep.dat are used, respectively.

NOTE:

A platform specific XML file needs to be used for HP ProLiant 100-series servers. If you

use the default name this may cause an error while running the CONREP utility.

CONREP –l (Load from Data File) Example Usage for HP ProLiant 100 series servers

To load the BIOS configuration settings from a previously captured/edited data file (in this case
“sl160zconrep.dat”) to an SL160z G6 server:

[root@ilo002481b08134 conrep]# ./conrep -l -xconrepSL160zg6_20090728.xml -fsl160zconrep.dat

conrep 3.00 - Scripting Toolkit Configuration Replication Program

Copyright (c) 2007-2012 Hewlett-Packard Development Company, L.P.

System Type: ProLiant SL160z G6

ROM Date : 07/28/2009

ROM Family : O33

Processor Manufacturer : Intel

XML System Configuration : conrep_SL160zg6_20090728.xml

Hardware Configuration : sl160zconrep.dat

Loading configuration from sl160zconrep.dat.

ASM values not set! aborting

CONREP Return code: 0

CONREP Data File Sample Contents for HP ProLiant 100 series servers

A typical data file generated by CONREP is similar to the following:

<Conrep_data>

<Section name="Controller_Order">

<Id0>0e 11 40 80 </Id0>

<Slot0>00 </Slot0>

<BusDev0>00 08 </BusDev0>

<Rest0>01 </Rest0>

<Id1>0e 11 ff ff </Id1>

<Slot1>00 </Slot1>

<BusDev1>00 78 </BusDev1>

<Rest1>c1 </Rest1>

Using CONREP

31

Advertising