A hp smh file locations, Hp smh file locations, Table a-1 hp smh file locations – HP Integrity rx4640 Server User Manual
Page 89

A HP SMH file locations
Table A-1 HP SMH file locations
HP-UX
Linux
Windows
Description
/opt/hpsmh
/opt/hp/hpsmh
SystemDrive\hp\hpsmh
HP SMH Root
The root of the
HP SMH installation.
/opt/hpsmh/lbin
/opt/hp/hpsmh/sbin/hpsmhd
SystemDrive\hp\hpsmh\bin\hpsmhd.exe
HP SMH Executable
The HP
SMH binary. A webapp can use
detection of this file's pressence
to verify that HP SMH is
installed on the system.
/opt/hpsmh/sslshare
/etc/opt/hp/sslshare/cert.pem
/etc/opt/hp/sslshare/file.pem
SystemDrive\hp\sslshare\cert.pem
SystemDrive\hp\sslshare\file.pem
Certificate and Key files
The
certificate and private key files
used by HP SMH. This is a
shared location used by a
number of management
applications. The keys may be
either 1024 or 2048 bits.
/opt/hpsmh/conf.common/smhpd.xml
/opt/hp/hpsmh/conf/smhpd.xml
SystemDrive\hp\hpsmh\conf\smhpd.xml
HP SMH XML
configuration
This file should
only be modified by HP SMH
itself.
/opt/hpsmh/conf
/opt/hp/hpsmh/conf/smhpd.conf
SystemDrive\hp\hpsmh\conf\smhpd.conf
HP SMH conf file
The conf file
is regenerated at every startup
and modification of the version
on disk.
/opt/hpsmh/data/htdocs
/opt/hp/hpsmh/data/htdocs
SystemDrive\hp\hpsmh\data\htdocs
2381 Document Root
The root
for documents served on port
2381 (HTTPS).
/opt/hpsmh/data/isdocs
/opt/hp/hpsmh/data/isdocs
SystemDrive\hp\hpsmh\data\isdocs
2301 Document Root
The root
for documents served on port
2301. Security restrictions allow
only particular HP SMH
documents to be served out of
this directory (HTTP).
/opt/hpsmh/data/cgi-bin
/opt/hp/hpsmh/data/cgi-bin
SystemDrive\hp\hpsmh\data\cgi-bin
cgi-bin Root
The root of
executable content.
/opt/hpsmh/data/help
/opt/hp/hpsmh/data/help
SystemDrive\hp\hpsmh\data\help
Help Root
The root where help
files are placed.
/opt/hpsmh/webapp
/opt/hp/hpsmh/webapp
SystemDrive\hp\hpsmh\webapp
Webapp XML files
The root
where webapp XML
configuration files are placed.
89
- Integrity rx7620 Server Integrity BL870c Server-Blade Integrity rx2660 Servers Integrity rx2600 Servers Integrity rx2800 i2 Server Integrity rx8620 Server Integrity rx6600 Server Integrity rx2620 Servers System Management Homepage-Software Integrity rx1620 Servers Integrity rx7640 Server Integrity rx8640 Server Integrity Superdome sx2000 Server Systems Insight Manager Integrity rx3600 Server Integrity BL870c i2 Server-Blade Integrity BL860c i2 Server-Blade Integrity Superdome sx1000 Server Integrity BL860c Server-Blade Integrity rx5670 Server