Validating storage, Validate storage profile, Field support commands – HP StoreAll Storage User Manual

Page 29: Repairing a storage system

Advertising
background image

Example 14 Dry run provisioning

hpsp_spt -cs -ctrlIp 10.20.12.101 -ap --dryRun
--------------------------------------------------
# Name WWN Drives Raid Size(GB)
--------------------------------------------------
1 HPIBX_VOL_1 N/A 5 5 1863.05*
2 HPIBX_VOL_2 N/A 6 5 2328.81*
3 HPIBX_VOL_3 N/A 6 5 2328.81*
4 HPIBX_VOL_4 N/A 6 5 2328.81*
--------------------------------------------------
*Approximate value

hpsp_spt -cs -ctrlIp 10.20.12.101 -ap --dryRun

Example 15 Actual provisioning

hpsp_spt -cs -ctrlIp 10.20.12.101 -ap

----------------------------------------------------------------------------------------------------
# Name WWN Controller Drives Raid Size(GB) Status
----------------------------------------------------------------------------------------------------
1 HPIBX_DAED6E3C041 00c0ff104cc000001da0495001000000 A 5 5 1861.12 OK
----------------------------------------------------------------------------------------------------

Summary:
1 Volume(s)
0 Spare(s)

Validating storage

Validate storage profile

Syntax

hpsp_spt -vs

hpsp_spt --validateStorage

Description

The --validateStorage command validates the storage configuration against the profile used
for configuring the storage. If the storage is not configured with any of the supported profiles, then
the validation of the configured storage fails with the appropriate error.

The validation scenarios include validating the configuration related to the number of spares,
drives, vdisks, volumes, RAID-level, host-access, and volume health

Example 16 Validate storage profile

# hpsp_spt -vs -ctrlIp 10.20.12.101 -usr manage -pwd \!manage
Validating with : 9320-SFF-EXP-300GB, 9320-SFF-STARTER-300GB

........
Valid Storage Configuration with profile: 9320-SFF-EXP-300GB, 9320-SFF-STARTER-300GB

Field support commands

WARNING!

All these are hidden commands and should only be used by an HP field engineer.

Repairing a storage system

Syntax

hpsp_spt -rp [--dryRun]

hpsp_spt --repair [--dryRun]

Command reference and examples

29