Starting and stopping usage monitoring, Starting usage monitoring, Usage monitor pane – HP XP Continuous Access Software User Manual

Page 166

Advertising
background image

Figure 66 Usage Monitor pane

Monitoring Switch: Usage monitor operation (see

Starting and stopping usage monitoring

).

• Enable: Monitoring is on.
• Disable: Monitoring is off.

NOTE:

When monitoring is stopped, the usage monitor graph is closed. The usage monitor graph only

appears when monitoring is running.

Gathering Interval: Data collection interval for usage monitoring between 1 and 15 minutes in

one minute increment. The default is 1.

NOTE:

When monitoring is stopped, the default (1) appears in the Gathering Interval box.

Update: Displays the most recent data sample time on the graph.

Graph: Displays remote I/O statistic information and status of the remote copy monitor.

Apply: Applies settings in the Usage Monitor pane to the array.

Cancel: Cancels settings in the Usage Monitor pane.

Starting and stopping usage monitoring

At each data sampling time interval, the usage monitoring function collects 1,440 pieces of data for each

LDEV and up to 1,440 pieces of data for the entire array.

Starting usage monitoring

1.

Select the Usage Monitor tab.

2.

In the Monitoring Switch box, select Enable.

3.

Select the sampling time interval (in minutes) from the Gathering Interval list. If the desired value is not

in the list, enter the time interval directly. You can enter from 1 to 15 minutes. The default is 1 minute.