Power supply leds – HP MSA Controllers User Manual
Page 71
HP P2000 G3 FC/iSCSI MSA System User Guide
71
Power supply LEDs
Power redundancy is achieved through two independent load-sharing power supplies. In the event of a
power supply failure, or the failure of the power source, the storage system can operate continuously on a
single power supply. Greater redundancy can be achieved by connecting the power supplies to separate
circuits. DC power supplies are equipped with a power switch. AC power supplies may or may not have a
power switch (model shown below has no power switch). Whether a power supply has a power switch is
significant to powering on/off.
NOTE:
See
on page 33 for information on power-cycling enclosures.
AC model
DC model
Table 19
LEDs — HP P2000 G3 MSA System power supply units — rear panel
LED
Description
Definition
1
Input Source Power Good
Green — Power is on and input voltage is normal.
Off — Power is off or input voltage is below the minimum
threshold.
2
Voltage/Fan Fault/Service Required
Amber — Output voltage is out of range or a fan is operating
below the minimum required RPM.
Off — Output voltage is normal.
1
2
1