7.3 Linux-specific Messages

This section describes messages that are logged on Linux systems only. These messages
will not be logged on any other platform.

3000

3000: Error trying to adjust system clock; error number was errnum

TimeSync could not adjust the local system time.

errnum

is the Linux system error that occurred.

Cause. TimeSync encountered a problem trying to adjust the local system time. In most
cases, this is a security-related issue.

Effect. TimeSync does not adjust the local system time.

Recovery. Verify that TimeSync is running with root permissions and that security policy
on the system is not set up to prevent time adjustments by the TimeSync process.

3001

3001: Error obtaining system time; could not proceed with time update

TimeSync could not obtain the local system time while preparing to set the time.

Cause. TimeSync could not retrieve the current local system time while preparing to
perform a clock update. In most cases, this is a security-related issue.

Effect. TimeSync does not adjust the local system time.

Recovery. Verify that TimeSync is running with root permissions and that security policy
on the system is not set up to prevent time adjustments by the TimeSync process.

3002

3002: Error trying to set system time; error number was errnum

TimeSync could not set the local system time.

errnum