Table 64 Prerequisite Hardware (HyperSwap)

Remarks

Description

Item

TPC-R is necessary at the primary site.

One unit each for the primary and
secondary sites.

Host

The configuration indicated on the left
must be used.

Primary site: two XP24000 or XP
P9500 disk arrays

Storage system

Secondary site: one XP24000 or XP
P9500 disk array

None

A bidirectional physical path (for
logical paths and delta resync control

Physical path

paths) connected by a Fibre Channel
cable is required between the storage
systems of the following sites:

•

Primary storage system

←→ Local

storage system

•

Primary storage system

←→

Remote storage system

•

Local storage system

←→ Remote

storage system

Table 65 Storage System Setting Items (HyperSwap)

Remarks

Description

Item

Use Remote Web Console for the setup.

A journal group is required for each
storage system.

Journal group

Timer type: SYSTEM

Use Remote Web Console for the setup.

At least one journal volume is required
for each storage system.

Journal volume

Use Business Continuity Manager for
the setup.

Command device

•

For the route in the forward
direction (Primary and local
storage system

→ Remote storage

system)

•

For the route in the reverse
direction (Remote storage system

→ Primary and local storage
system)

Use Remote Web Console or Business
Continuity Manager for the setup.

Logical path

•

An inter-control unit logical path
(bidirectional) must be established
between the primary and local
storage system.

•

An inter-disk controller logical path
(bidirectional) must be established
between the primary and remote
storage system.

•

An inter-disk controller logical path
(bidirectional) must be established
between the local and remote
storage system.

Use Remote Web Console for the setup.

Add a delta resync control path
(bidirectional) between storage
systems.

Delta resync control path

210