Mini-sas y-cable options – HP ProLiant DL380e Gen8 Server User Manual

Page 48

Advertising
background image

Hardware options installation 48

8.

Connect the common end of the Mini-SAS Y-cable to the controller option.

9.

Install the PCI riser cage ("

Install the PCI riser cages

" on page

26

).

10.

Route the split ends of the Mini-SAS Y-cable along the side of the system board towards the front chassis,
and then connect the cable to the drive backplane.
The Mini-SAS cable routing from the secondary PCI riser cage is only supported in the 8+8 SFF drive
configuration.

11.

Connect the rest of the drive cables required in this drive configuration. For more information, see
"Storage cabling (on page

83

)."

12.

Install the PCI riser cage ("

Install the PCI riser cages

" on page

26

).

13.

If you intend to use an FBWC module and capacitor pack, install these options now ("

Installing the

FBWC module and capacitor pack

" on page

51

).

14.

Install the air baffle (on page

24

).

15.

Install the access panel (on page

24

).

16.

Install the server into the rack ("

Installing the server into the rack

" on page

33

).

17.

Power up the server (on page

20

).

CAUTION:

To prevent improper cooling and thermal damage, do not operate the server unless

all bays are populated with either a component or a blank.

18.

Install the drives ("

Installing a hot-plug drive

" on page

37

).

Mini-SAS Y-cable options

The Mini-SAS Y-cables in these option kits support the following drive configurations.

Drive configuration

Mini-SAS Y-cable required

8 LFF

690 mm

8 SFF

540 mm

8+8 SFF

1

540 mm and 780 mm

12 LFF

2

540 mm

25 SFF

2

690 mm

1

This drive configuration requires the installation of two HP Smart Array P430 controller boards in the full-height side of

the primary PCI riser cage.

2

With expander backplane

To connect the cable option:

1.

Power down the server (on page

20

).

Advertising