Return codes generated by the ktgethda command, Parameters, Return codes – HP XP P9500 Storage User Manual

Page 91

Advertising
background image

1

PREFIX(prefix)

1

SN(serial-number)

Parameters

STEM(stem-name-1)

~<REXX prefix consisting of 64 or fewer characters>

Specify the prefix (any value) of the host-discovered array structure to which the information will
be loaded from the disk configuration definition file. This value must end with a period.

MSG(stem-name-2)

~<REXX prefix consisting of 64 or fewer characters>

Specify the prefix (any value) of the message structure that stores messages generated by this
command. This value must end with a period.

PREFIX(prefix)

~<prefix character string of 25 or fewer characters>

Specify the prefix of the disk configuration definition file to be read.

SN(storage-system-serial-number)

~<5-12 alphanumeric characters>

Specify the serial number of the storage system from which information will be read.

Reference note

If the

KTGETHDA

command with the same value specified for the

STEM

parameter is executed multiple

times, all execution results are valid as long as the

SN

parameter, which specifies a storage system,

has a unique value. If a host-discovered array structure has already been set by executing another
CLI command, information for the same REXX variable name will be overwritten.

Return codes

The following table lists and describes the codes returned when the

KTGETHDA

command terminates.

If the commands do not terminate normally, refer to the resulting error messages for details.

Table 17 Return codes generated by the KTGETHDA command

Meaning

Return code

The command ended normally.

0

An unknown XML attribute or element is found in the input file.

4

XML data in the input file ends with an invalid structure.

36

An error occurred during reading of the file.

An error occurred during writing of the REXX variables.

40

The command ended due to invalid processing.

44

The command ended due to an invalid parameter. The possible cause is as
follows:

The parameters were specified incorrectly.

48

The command ended due to an incorrect execution method. The possible
causes are as follows:

The

MSG

parameter was specified incorrectly.

Installation was not performed correctly.

52

User Guide

91