HP StorageWorks XP Remote Web Console Software User Manual

Page 99

Advertising
background image

Table 40 Error Code and Error Contents When Operating RAID Manager (continued)

Error Contents

Error Code (SSB2)

Error Code (SSB1)

3.

Because the volume specified as the P-VOL was the S-VOL of the
pair that was being split by quick split, the pair creation was
rejected.

4.

Because the VLL setting of the P-VOL was different from that of the
S-VOL, the quick restore operation was rejected.

5.

Because the specified P-VOL and S-VOL were the FlashCopy
Mirroring pair, the pair operation was rejected.

6.

Because the pair status of the specified P-VOL and S-VOL was PSUE,
the quick restore operation or the reverse copy operation was
rejected.

7.

Because the specified P-VOL and the S-VOL was the L2 pair, the
quick restore operation or the reverse copy operation was rejected.

8.

The At-Time Split operation on a consistency group was rejected
because some of the pairs in the consistency group were being
resynchronized, being split, or already suspended.

9.

Because the pair status of the P-VOL, the S-VOL, or both showed
that the pair could not receive the issued command, the pair
operation was rejected.

Because the volume specified as the S-VOL was online to the host, the
pair operation was rejected.

2312

Because the volume specified as the S-VOL was the S-VOL of another
XP Business Copy pair whose pair status was PSUS, the pair creation
was rejected.

2314

Because the P-VOL of the specified pair was online to the host, the
quick restore operation or the reverse copy operation was rejected.

231F

b9a0/b9a1/b9a2/

b9a5/b9a6/b9ae/

Because the necessary shared memory was not installed, or the
initialization was not completed, the pair operation was rejected.

2322

b9af

Because the number of slots of the volume specified as the P-VOL
exceeded the upper limit, the pair operation was rejected.

2324

Because the number of slots of the volume specified as the S-VOL
exceeded the upper limit, the pair operation was rejected.

2325

Because the volume specified as the P-VOL already had three S-VOLs,
the pair creation was rejected.

2326

Because the node volume specified as the P-VOL already had two
S-VOLs, the pair creation was rejected.

2327

Because the pair configuration exceeded the number of layers of the
cascade configuration, the pair operation was rejected.

2328

Because the volume specified as the S-VOL was the S-VOL of an existing
pair, the pair operation was rejected.

2329

Because pairs that would exceed the license capacity were going to
be created, the Create Pair operation was rejected.

232a

Because the volume specified as the P-VOL was allocated as the
destination of XP Auto LUN, the pair operation was rejected.

232F

The pair operation was rejected due to one of the following causes:

2331

1.

The volume specified as the P-VOL was a reserved volume.

2.

The volume specified as the P-VOL was the source volume for XP
Auto LUN.

3.

The capacity of the specified P-VOL and the S-VOL was not the
same.

Because the volume specified as the P-VOL already had three S-VOLs,
the pair creation was rejected.

2332

Troubleshooting When Using RAID Manager