Set enclosure serial_number, Set enclosure uid, Set iox uid – HP Integrity Superdome 2 Server User Manual
Page 75: Set llf interval

SET ENCLOSURE SERIAL_NUMBER
•
Command:
SET ENCLOSURE SERIAL_NUMBER "<serial number>"
•
Description:
Sets the enclosure serial number.
•
Access level/Bay level:
OA Administrator
•
Restrictions:
Must be 10 characters in length and includes all alphanumeric, underscore (_), and dash (-)
characters.
SET ENCLOSURE UID
•
Command:
SET ENCLOSURE UID {ON | OFF}
•
Description:
Turns the UID LED of the enclosure on or off.
•
Access level/Bay level:
OA Administrator, OA Operator
•
Restrictions:
None
SET IOX UID
•
Command:
SET IOX UID { ALL | <iox number> [{-|,}] <iox number>]} {ON | OFF}
•
Description:
Turns the UID LED of the specified IOX enclosures on or off.
•
Access level/Bay level:
OA Administrator, OA Operator, OA user
•
Restrictions:
You must be logged on to the monarch OA to perform this command.
SET LLF INTERVAL
•
Command:
SET LLF INTERVAL <seconds>
•
Description:
Set the Link Loss Failure Interval
•
Access level/Bay level:
Operator, Administrator
•
Restrictions:
Must have OA permission to perform this command.
SET ENCLOSURE SERIAL_NUMBER
75