DETERMINE INSTALLATION HEIGHT

• Telescopic duct covers are provided to conceal

the ductwork running to the ceiling.

• This hood can be installed for recirculating

operation. Recirculating Kit included with hood.

NOTE: Installation height should be measured from

the cooking surface to the straight portion of the

hood.
The vent hood must be installed 24” min. and
µPD[DERYHWKHFRRNLQJVXUIDFH7KHKRRG

installation height, from the cooking surface to the

bottom of the hood, depends upon ceiling height

and duct cover limitations.

Installation Preparation

24” Min.

µ0D[

36” Min.

*Based on 36” countertop height

PV970, PV976

Upper

Duct

Cover

25.81

Lower Duct Cover

27.56

Counter to Hood Height

Actual

*Possible

Ceiling

*Possible

VENTED

RECIRCULATING

Height

Installation Height

Installation Height

7’11”

24” to 30”

24”

8’ 0”

24” to 30”

24” to 25”

8’ 1”

24” to 30”

24” to 26”

8’ 2”

24” to 30”

24” to 27”

8’3”

24” to 30”

24” to

28”

8’ 4”

24” to 30”

24” to 29”

8’ 5”

24” to 30”

24” to 30”

8’ 6”

24” to 30”

24” to 30”

8’ 7”

24” to 30”

24” to 30”

8’ 8”

24” to 30”

24” to 30”

8’ 9”

24” to 30”

24” to 30”

8’ 10”

24” to 30”

24” to 30”

8’ 11”

24” to 30”

24” to 30”

9’ 0”

24” to 30”

24” to 30”

9’ 1”

24” to 30”

24” to 30”

9’ 2”

25” to 30”

24” to 30”

9’ 3”

26” to 30”

24” to 30”

9’ 4”

27” to 30”

24” to 30”

9’ 5”

28” to 30”

24” to 30”

9’ 6”

29” to 30”

24” to 30”

9’ 7”

30”

25” to 30”

9’ 8”

26” to 30”

9’ 9”

27” to 30”

9’ 10”

28” to 30”

9’ 11”

29” to 30”

10’

0”

30”

10’ 1”

10’

2”

10’

3”