– The inverter is not functional.



– The vehicle’s battery voltage is more than 15.5 volts. The inverter will

automatically restart after the voltage drops below 15.0 volts.


– The continuous load demand from the device exceeds the inverter’s

wattage output.


– The inverter is overheated and automatically turns off for a period of 1 to

3 minutes to cool. Make sure the inverter is well ventilated. It will automatically

restart after it cools.


– The vehicle’s battery voltage is less than 10.5 volts.



– Short circuit, power surge or overload in the device.

IF THE INVERTER’S FUSE BLOWS

Your power inverter is fitted with a fuse, which should not have to be replaced

under normal operating conditions. A blown fuse is usually caused by reverse

polarity or a short circuit within the device or equipment being operated.
If the fuse does blow, take the inverter to a qualified technician for repair.

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

REASON/SOLUTION

Alarm is on.

Display shows . Device

demands too much surge

power.

Device has a short circuit

Display shows . 12 volt

battery is too low.

Display shows voltage

between 10.5 and 11.0

volts.

Display shows . 12 volt

voltage is too high.

Cycle the inverter power OFF

and ON. If problem persists,

use a larger inverter or a

smaller device.

Remove the defective device.

Recharge/replace battery.

12V battery is low. Recharge or

replace battery. The inverter will

automatically shut off after battery

voltage reaches 10.5 volts.

If in a vehicle, repair/replace

the alternator or charging

system. Use a properly sized

and rated 12 volt battery. If

the input voltage returns to 15

volts or less, the inverter will

automatically restart.