Zoo Med MicroPump 104 User Manual
English, Safety warnings, For uk only
SAFETY WARNINGS
♦ If the unit is supplied with an grounded plug it must be
connected to an grounded socket.
♦ Always disconnect all electrical appliances from the power
before placing your hands in the water.
♦ The line cord cannot be replaced or repaired. Should the cord
become damaged the appliance must be discarded.
♦ This unit is for indoor use only.
♦ This unit must not be used in swimming pools or bathrooms.
♦ This appliance has been designed for use in fluids up to 95°F
(35°C.)
For UK only
The leads of this unit must be connected as follows: Blue or
Black to Neutral or Black-coloured terminal; Brown to Live or
Red-coloured terminal. Units intended for outdoor use have
a Green or Green/Yellow earth wire and this must be
connected to the Earth terminal
on the plug.
This unit is fitted with a BS1363 13A plug. Should the fuse
need to be replaced, a 3A ASTA approved BS1362 must be
used. If your socket is not suitable for the plug then plug must
be removed and an appropriate one fitted.
Warning:
Proper care must be taken in discarding a plug
which has been removed by cutting the cable.
♦ Check that the voltage shown on the label of the unit
corresponds to the voltage of the mains supply.
♦ Connect the unit only to power supplies with residual
current circuit breaker (RCCD) with sensitivity of 30 mA.
ADJUSTING THE FLOW*
Rotate the control valve toward min. or max. indicator
(fig. 1) as necessary.
*Note: Pumps included in Zoo Med’s Repti Rapids Cascading
Waterfall are grounded and do not have adjustable water
flow.
ENGLISH
FIG. 1
FIG. 2
FIG. 3
SPARES
RECHANGES
ERSATZTEILE
RICAMBI
50Hz
60Hz
RECAMBIOS
PMC-13E PMC-13
Multi-function pump
Pompe multi-fonctions
Tauchpumpe
Pompa multifunzione
Bomba multi-función
MAINTENANCE
Regular cleaning of the filter, the rotor and the pump
chamber (fig. 2) is recommended to remove any debris and
lime-scale which could block the unit.
The motor is fully encapsulated and self protected against
overheating and needs no particular care.
If the pump fails to work, first check the electrical supply,
connections, circuit breaker etc. If these are correct, the
pump needs to be cleaned.
CLEANING
Prior to any work, disconnect all immersed electrical
equipment from the power. Remove the strainer from the
motor housing and open it. Pull off the rotor from its
location (fig. 3). Carefully rinse all components under
running water with a non metallic brush. If necessary
remove lime-scale by leaving the components immersed in
vinegar or lemon juice for few hours.
WARRANTY
This unit has been manufactured according to IEC EN 60 335-
2-41 safety standards, and with the highest quality materials and
accuracy.
This product is guaranteed against manufactured defect for 12
months from date of purchase.
In the unlikely event of a fault, the unit should be returned to Zoo
Med within one year of purchase, together with the sales receipt.
It is important that the unit should not have been tampered with.
Please note, the guarantee is not valid if the defects are caused
by tampering, negligence, misuse or non observing the safety
warnings.
No responsibility is assumed for indirect damage that may result
from the use of this appliance.
Item# MP-10