Pc control command reference guide – Kenwood TS-990S User Manual

Page 54

Advertising
background image

– 53 –

PC Control Command referenCe guide

SL

Receive Filter Low-cut Frequency/ Wide Frequency

Parameters:

P1

0: Main Band

1: Sub Band

P2 (Low-cut Frequency ID/ Wide Frequency ID)

P2

Low-cut Freq. (Hz)

Wide Freq. (Hz)

AM

Other

SSB

CW

FSK

PSK

00

0

0

50

50

250

50

01

100

50

80

80

300

80

02

200

100

100

100

400

100

03

300

200

150

150

500

150

04

300

200

200

1000

200

05

400

250

250

1500

250

06

500

300

300

300

07

600

400

400

400

08

700

500

500

500

09

800

600

600

600

10

900

1000

1000

1000

11

1000

1500

1500

1500

12

2000

2000

13

2200

2500

14

2400

15

2600

16

2800

17

3000

(An error occurs when entering an ID with no assigned frequency

for the setting command. Entering a value of 99 results in the

initial value being entered.)

Set

1

2

3

4

5

6

7

8

9

10

S

L

P1

P2

P2

;

Read

1

2

3

4

5

6

7

8

9

10

S

L

P1

;

Answer

1

2

3

4

5

6

7

8

9

10

S

L

P1

P2

P2

;

SM

S-Meter/Power Meter

Parameters:

P1

0: Main Band

1: Sub Band

P2 (Meter oscillation)

0000 ~ 0070: Meter value (in dots)

(This value shows the oscillation (number of dots) of the

transceiver digital meter. The SM command reads the S-meter

during reception and the power meter during transmission. While

receiving, the Sub band value is returned as 0000.)

Read

1

2

3

4

5

6

7

8

9

10

S

M

P1

;

Answer

1

2

3

4

5

6

7

8

9

10

S

M

P1

P2

P2

P2

P2

;

SP

Split Operation Frequency Setting

Parameters:

P1

0: During no opertaion/ Complete the setting

1: During the setting/ Start the setting

2: Cancel the setting (Set only)

(When using Setting 2, set the P1 parameter to 0. The “SPLIT”

LED blinks during this setting.)

P2 (Shift direction)

0: + shift

1: – shift

P3 (Shift amount)

1 ~ 9 (in kHz)

• When performing setting 2, Split operation activates

automatically.

Set 1

1

2

3

4

5

6

7

8

9

10

S

P

P1

;

Set 2

1

2

3

4

5

6

7

8

9

10

S

P

P1

P2

P3

;

Read

1

2

3

4

5

6

7

8

9

10

S

P

;

Answer

1

2

3

4

5

6

7

8

9

10

S

P

P1

;

SQ

Squelch Level

Parameters:

P1

0: Main Band

1: Sub Band

P2

000 ~ 255 (in steps of 1): Squelch level

Set

1

2

3

4

5

6

7

8

9

10

S

Q

P1

P2

P2

P2

;

Read

1

2

3

4

5

6

7

8

9

10

S

Q

P1

;

Answer

1

2

3

4

5

6

7

8

9

10

S

Q

P1

P2

P2

P2

;

Advertising