6.1.3.2 Connection of the power supply line

Electrical connections must be performed

with the power supply disconnected and

the circuit-breaker open.

When commencing installation make sure

that the specifications for the power supply

for the installation correspond with those

required by the device.

Earth cable should be about 10mm longer

than the other two, so that it will not be

disconnected accidentally if pulled.

Make sure that the power source and

connecting cables are suitable for the

power consumption of the system.

The power supply cable should also be

covered by the silicone sheath (01) supplied

for this purpose. The silicone sheath must

be fastened with the corresponding tie (02).

Depending on the version, the device can be

provided with different power supply voltages. Their

value is shown on the product identification label (4.2

Product markings, page 8).

01

02

N

L a

Fig. 9

Connect the power supply cables to the J2 terminal

as described in the table.

CONNECTION OF THE POWER SUPPLY LINE

Colour

Terminals

Power supply 24Vac
Defined by the installer

N (Neutral)

Defined by the installer

L (Phase)

Yellow/Green

GND

Power supply 230Vac
Blue

N (Neutral)

Brown

L (Phase)

Yellow/Green

GND

Power supply 120Vac
Blue

N (Neutral)

Brown

L (Phase)

Yellow/Green

GND

Tab. 2

Use a Class 2 listed UL tranformer,

compliant with the Standards in force, only

for products marked UL, powered at 24Vac.

To connect the power supply line use the

appropriate junction-box (UPTJBUL). For

further information, refer to the product

use and installation manual.