Lyndex-Nikken Shrink Fit Machine Instructions User Manual

Page 9

Advertising
background image

ELCO

Shrink fit unit Start.2

27/04/2010

Page 9/19

Unlock the column:

Take off the transportation pieces, located under the inductor, in front face.

Electric connection :

Connect the unit to the three-phase network 3x 200V/240V alternating 50/60Hz +

ground/earth (neutral is not used, no order in phases).

The electric line must be connected to a circuit-breaker 32A curve C and protected

by a 30mA differential.

4.3

Moving the unit

For all moving of the unit, switch the unit and compressed air off.

The unit and the central column must remain upright. The unit must be moved with the

usual precautions, taking it under its structures. Make sure that nothing can fall and hurt

somebody.

In case of moving the unit with horizontal column, replace the transportation pieces in

order to lock the inductor.