Unlock the column:
Take off the transportation pieces, located under the inductor, in front face.
Electric connection :
Connect the unit to the three-phase network 3x 200V/240V alternating 50/60Hz +
ground/earth (neutral is not used, no order in phases).
The electric line must be connected to a circuit-breaker 32A curve C and protected
by a 30mA differential.
4.3
Moving the unit
For all moving of the unit, switch the unit and compressed air off.
The unit and the central column must remain upright. The unit must be moved with the
usual precautions, taking it under its structures. Make sure that nothing can fall and hurt
somebody.
In case of moving the unit with horizontal column, replace the transportation pieces in
order to lock the inductor.