Samlex America PSE-24275A User Manual

Page 17

Advertising
background image

Page 16

Battery Current & Voltage Bar Graph Meters (GREEN, YELLOW, RED).

d

Current Indicator. This illuminated Bar Graph monitors the current being

drawn from the battery by the inverter. Depending on the amount of current being
drawn, the Bar Graph reading generally will be in the GREEN or YELLOW zone.
When the reading rises to the RED zone, the inverter may automatically shut down.

e

Two Standard North American NEMA 5-15R Receptacles are provided on

models PSE-24125A and PSE-24175A. On PSE-24275A, the output is available
from unconnected, Line (BLACK), Neutral (WHITE) and chassis/equipment ground
(GREEN) wires for connection to an external breaker panel. A plate with standard
North American NEMA 5-15 receptacle(e) wired in series with a 15 A circuit
breaker (j) is provided as an accessory. Use this receptacle if you require power to be
drawn from the front panel. (This will require connection). As this receptacle(e) is
fed through a 15A breaker (j), the power drawn from here should be limited to 1500
watts.

f

Remote Operation Socket. The inverter is designed to be operated from a

remote location via the remote control switch which plugs into this socket. This
optional accessory is available from Samlex.

g

High Speed Cooling Fan. This fan will turn on automatically when the

internal temperature exceeds the designed parameters for safe operation. The
cooling fan will automatically turn off when the temperature drops to a safe
operating level. This fan does not run continuously.

h

Power Input Terminals (WHITE or BLACK/Negative, RED/Positive)

i

Chassis Ground Terminal Lug

j

Circuit Breaker. This is provided for PSE-24275A

k

Punched Holes. These holes are provided for entry of cables going to the

external Breaker Panel (when hard wired)

Advertising
This manual is related to the following products: