Campbell Scientific CS451/CS456 Pressure Transducer User Manual

Page 17

Advertising
background image

CS451/CS456 Submersible Pressure Transducer

Measurement Ranges:

Pressure (psig) Pressure (kPa) Depth of fresh water
0 to 2.9

0 to 20

0 to 2 m (6.7 ft)

0 to 7.25

0 to 50

0 to 5.1 m (16.7 ft)

0 to 14.5

0 to 100

0 to 10.2 m (33.4 ft)

0 to 29

0 to 200

0 to 20.4 m (67 ft)

0 to 72.5

0 to 500

0 to 50.9 m (167 ft)

0 to 145

0 to 1000

0 to 102 m (334.5 ft)

Accuracy:

±0.1% full scale range TEB* or

±0.05% full scale range TEB**

Resolution:

0.0035% full scale range

Overpressure:

2x pressure range

Dry Storage Temperature:

–10 to 80 °C

Sensor will be damaged if it is encased in frozen liquid.

Operating Temperature:

0 to 60 °C

Temperature Accuracy:

±0.2 °C

Maximum Cable Length:

SDI-12 (one transducer

connected to a single port): ~475 m (1500 ft)

SDI-12 (10 transducers

connected to a single port): 60 m (200 ft)

RS-232:

60 m (200 ft)

Cable Type:

5 Conductor, 26 AWG

Hytrel Jacket

Body Material:

CS451 – 316L Stainless Steel

CS456 – Titanium

Element Material:

CS451 – 316L Stainless Steel

CS456 – Hastelloy

Top Cone Material:

Delrin

Length:

213.36 mm (6.875 in)

Diameter:

21.34 mm (0.84 in)

Distance from pressure sensor interface

(black line etched on housing) to:

End of NPT fitting:

2.54 cm (1 in)

End of standard nose cone: 2.3 cm (0.9 in)

End of weighted nose cone: 9.9 cm (3.9 in)

CAUTION

7