2 example programs, 1 cr1000 example program – Campbell Scientific LI190SB LI-COR Quantum Sensor User Manual

Page 12

Advertising
background image

LI190SB Quantum Sensor

5.2 Example Programs

The following programs measure the LI190SB every 10 seconds, and convert
the mV output to µmoles s

-1

m

-2

and mmoles m

-2

. Both programs output an

hourly average flux (µmoles s

-1

m

-2

) and a daily total flux density (mmoles

m

-2

). Wiring for the examples is given in Table 5-2. Multipliers in the

example programs are based upon a sensor with a calibration constant of 6.45
µA/1000 µmoles s

-1

m

-2

.

TABLE 5-2. Wiring for Example Programs

Color Description

CR1000 CR10X

Red Signal

1H 1H

*Black Signal

Reference 1L

1L

Clear Shield

G

*Jumper to AG or

with user supplied wire.

5.2.1 CR1000 Example Program

'CR1000

'Declare Variables and Units
Public PAR_Den
Public PAR_Tot

Units PAR_Den=µmol/s/m²
Units PAR_Tot=mmol/m²

'Define Data Tables
DataTable(Table1,True,-1)
DataInterval(0,60,Min,10)
Average(1,PAR_Den,FP2,False)
EndTable

DataTable(Table2,True,-1)
DataInterval(0,1440,Min,10)
Totalize(1,PAR_Tot,IEEE4,False)
EndTable

'Main Program
BeginProg
Scan(10,Sec,1,0)

'LI190SB Quantum Sensor measurements PAR_Tot and PAR_Den:

VoltDiff(PAR_Den,1,mV25,1,True,0,_60Hz,1,0)

'Use 20 mV range for CR3000, CR5000

'Set negative values to zero

If PAR_Den<0 Then PAR_Den=0

PAR_Tot=PAR_Den*2.56686

'Multipliers will differ for each sensor and scan rate

PAR_Den=PAR_Den*256.686

'Call Data Tables and Store Data

CallTable(Table1)
CallTable(Table2)
NextScan
EndProg