A.J. Antunes & Co SI-XL 9700902 User Manual

General, Equipment setup

Advertising
background image

Scale InhIbItor SyStem (P/n 9700901)

1-877-392-7854 Fax: 630-784-1000

Page 1 of 2

P/N 1010449 Rev. A 03/12

TOOLS:

• Mounting Hardware (Not Provided)

• Drill with bits

• Tape Measure

• Pipe Wrenches

• Adjustable Wrenches

• Level

• Pipe Dope, Thread Seal Tape, or Thread Sealing Cord

• Screwdriver (Flat Blade and Phillips)

• Two Gallon Bucket

• Fresh 6% unscented liquid chlorine bleach

PARTS INCLUDED:
1 - Bracket, Filter Std. Housing w/ screws (P/N 0505639)

1 - Housing, Bowl, and Head (2180243)

1 - Wrench, Filter (2180244)

1 - Tee 3/4” NPT (2190130)

1 - Nipple, Hex 3/4” NPT x 1-1/2” LG (2190144)

1 - Scale Inhibitor Element Kit (7000540)

1 - Scale Inhibitor System Instruction Sheet (P/N 1010449)

cautIon

Do not use this system with water that is microbiologi-

cally unsafe or of unknown quality without adequate dis-

infection installed before or after the system.

General

If you experience any problems with these instructions, or if any

parts are damaged or missing, contact the factory Technical

Service Department at 630-784-1000 or toll free in the U.S. at

877-392-7854.
The Scale Inhibitor System provides mineral scale prevention

by feeding scale control compounds into the water. It should be

installed upstream of any ice making, beverage, or steam equip-

ment.

equipment Setup

When installing the system, pay attention to the following guide-

lines:

• Do not install above electrical equipment.
• Allow space below the Scale Inhibitor Housing for Element

change out.

PlumbInG
note: this system is designed to be used on tap water not

to exceed 100°F (38°c) or 100 psig (690 kPa). the kit must

be connected to the colD water line. Do not connect the

kit to the hot water line.

The Scale Inhibitor System has the following connections:

• Inlet

3/4” NPT

• Outlet

3/4” NPT

When making a plumbing connection to the System, use a

back-up wrench on the supporting plumbing. Always use a

quality, approved pipe sealant or thread seal tape on the pipe

threads. Be careful not to get the pipe sealant inside the pipe

when making connections.

DO NOT over tighten the connections. The use of plastic fittings

when connecting to the plastic head will reduce the possibility of

cracking the head due to over tightening.

If soldered plumbing is used, do not apply heat to, or near, the

Head. The use of union (o-ring seal) connections is highly rec-

ommended for ease of installation and future servicing.

cautIon

this equipment must be installed to comply with the

basic plumbing code of the building officials and code

administrators, Inc. (boca) and the Food Service

Sanitation manual of the Food and Drug administration

(FDa).

cautIon

Water pressure must not exceed 100 psig. to reduce

water pressure, install a water pressure regulator and set

the water pressure to below 100 psig.

Head Bracket

and Screws (8)

Housing

Clear

Head

O-Ring

(incl. with Head)

Scale

Inhibiter

Element

Filter Wrench

Figure 1. Scale Inhibitor System

a. J. antuneS & co. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188

Advertising
This manual is related to the following products: