Pathway DMX QConnect Software for CR Manual User Manual

Page 29

Advertising
background image

DMXQConnect for CR - User Guide

Command Reference

26

Splash: This refers to the initial screen and graphic seen when

DMXQConnect is first started. You can specify a specific display time duration
or have the splash hold until “a Key is Pressed or a Mouse is Clicked”.


Display: You can choose to have the Command Line and Status Line display

at the bottom of your screen, by click-checking the appropriate boxes.


Comm Port: This screen defines the hardware connection parameters

between your PC and the DMXPathfinder. See Chapter 2: Communications
Setup
for instructions. WARNING: Changing these settings may result in a
loss of your DMXPathfinder connection.


Database Backup: As with any other computer application, it is wise to make

backups of your DMXQConnect data. QConnect will remind you to make a
backup as the program is being closed, after the specified number of uses.

DMXPathfinder Options

These will provide the means to remotely select patch mode and configure

your DMXPathfinder interface. A display with two tabs appears:


DMXPathfinder Patch Mode: Lets the user remotely toggle the

DMXPathfinder patch configuration between the two file data stores (Backup
and Normal) from the PC. A Clear function is included which, when chosen,
completely strikes the current patch configuration from the Pathfinder and
erases the Normal patch data from its memory. The Backup patch data in the
Pathfinder’s memory is not affected.


DMXPathfinder Hardware Configuration: Use the mouse to click on your

selections. IMPORTANT: These settings are typically made once during
system setup, and will not need to be changed unless your system
hardware is modified.
WARNING: Incorrect settings or modifications
may result in incorrect operation.


The model (DMXPathfinder LR or Classic) must be set to match the connected

hardware. DMXPathfinder LR is identified as such on the front face of the
modules. Classic hardware is only identified as DMXPathfinder on the face.


The Diagnostic Patch selection provides a means for the user or technician to

analyze the patch file output data format and content. When Display Patch
Debug Form is click-checked, a debug window will open every time a PC-to-
Pathfinder patch file transfer is initiated. The window contains a “dump” of the
actual bit-by-bit patch data that was just sent to the Pathfinder. Normally you
should leave this selection set to Do NOT Display Patch Debug Form.


Input and Output card selection is discussed in detail in Chapter 3: Setting Up

the System.