RECOMMENDED OPERATING CONDITIONS

(DGND = 0V; all voltages with respect to ground)

Notes: 3. Applying power to VD+ prior to VA+ creates a SCR latch-up condition. Refer to Figure 2 for the

recommended power connections.

ABSOLUTE MAXIMUM RATINGS

(AGND, DGND = 0V, all voltages with respect to ground.)

Parameter

Symbol Min

Typ

Max

Unit

DC Power Supplies:

Positive Digital
Positive Analog
Negative Analog
(VD+) - (VA+) (Note 3)

VD+

VA+

VA

-

4.75
4.75

-4.75

-0.3

5.0
5.0

-5.0

-

VA+

5.25

-5.25

0.0

V
V
V
V

Ambient Operating Temperature

T

A

0

25

70

°C

Parameter

Symbol Min

Max

Unit

DC Power Supplies:

Positive Digital
Positive Analog
Negative Analog

VD+

VA+

VA-

-0.3
-0.3

0.3

(VA+)+ 0.3

6.0

-6.0

V
V
V

Input Current, Any Pin Except Supply

I

in

-

±10

mA

Digital Input Voltage

V

IND

-0.3

(VA+) + 0.3

V

Ambient Operating Temperature (power applied)

T

A

-55

+125

°C

Storage Temperature

T

STG

-65

+150

°C