Cs3310, Recommended operating conditions, Absolute maximum ratings – Cirrus Logic CS3310 User Manual
Page 4
CS3310
4
DS82F1
RECOMMENDED OPERATING CONDITIONS
(DGND = 0V; all voltages with respect to ground)
Notes: 3. Applying power to VD+ prior to VA+ creates a SCR latch-up condition. Refer to Figure 2 for the
recommended power connections.
ABSOLUTE MAXIMUM RATINGS
(AGND, DGND = 0V, all voltages with respect to ground.)
Parameter
Symbol Min
Typ
Max
Unit
DC Power Supplies:
Positive Digital
Positive Analog
Negative Analog
(VD+) - (VA+) (Note 3)
VD+
VA+
VA
-
4.75
4.75
-4.75
-0.3
5.0
5.0
-5.0
-
VA+
5.25
-5.25
0.0
V
V
V
V
Ambient Operating Temperature
T
A
0
25
70
°C
Parameter
Symbol Min
Max
Unit
DC Power Supplies:
Positive Digital
Positive Analog
Negative Analog
VD+
VA+
VA-
-0.3
-0.3
0.3
(VA+)+ 0.3
6.0
-6.0
V
V
V
Input Current, Any Pin Except Supply
I
in
-
±10
mA
Digital Input Voltage
V
IND
-0.3
(VA+) + 0.3
V
Ambient Operating Temperature (power applied)
T
A
-55
+125
°C
Storage Temperature
T
STG
-65
+150
°C