Duff-Norton SK6415-200 (SPA Series AC) User Manual

Page 11

Advertising
background image

11

to install terminals on switch terminals tabs with

needle-nose pliers and care should be taken not to

damage terminal tab or switch (see Figure 6-3).

d. Feed terminal wires, (17) red, (18) blue, fuse

jumper wire, and motor lead through 1/2"

tapped hole in cover capacitor box outside of

cover.

e. Moving wires out of the way, insert capacitor (5)

into box (termials up) and attach motor lead wire

(large connectors) to capacitor terminals. (Red on

one pair of capacitor terminals and blue on the other

pair of capacitor terminals.)

f. Insert insulation (4) and assemble gasket (3)

and cover (2) with screws (1).

g. Adjust actuator limit switch settings per

instructions in paragraph 2-2.

h. If actuator has potentiometer, refer to

position indicator installation and calibration

instructions in Paragraph 2-4.

I. Attach gasket (12) and cover (11) with screws (1).

ASSEMBLY IS NOW COMPLETE.

6415-200 manual 10/10/06 11:46 AM Page 11