Drain pump – AEG L61470WDBI User Manual
Page 24
MAX
3.
Remove the top part of the liquid ad-
ditive compartment.
4.
Clean all the parts with water.
5.
Clean the dispenser recess with a
brush.
6.
Put back the dispenser in the recess.
DRAIN PUMP
The pump should be inspected regularly
and particularly if:
• the appliance does not empty and/or
spin;
• the appliance makes an unusual noise
during draining due to objects such as
safety pins, coins etc. blocking the
pump;
• a problem with water draining is detec-
ted (see chapter “Troubleshooting” for
more details).
WARNING!
Before unscrewing the pump cov-
er, switch the appliance off and
remove the mains plug from the
socket.
Proceed as follows:
1.
Unplug the appliance.
2.
If it is necessary, wait until the water
has cooled down.
A
B
3.
Place a container close to the pump
to collect any spillage.
4.
Release the emergency emptying
hose (B), place it in the container and
remove its cap cover.
24 www.aeg.com