Adjusting the air flowdirection – Sharp AY-XPC9JR User Manual

Page 9

Advertising
background image

GB-7

ENGLISH

VERTICAL AIR FLOW DIRECTION

1

Press the SWING button on the remote

control once.

• The vertical adjustment louvres will swing

continuously.

2

Press the SWING button again when the

vertical adjustment louvres are at the

desired position.

Adjustment range

COOL and DRY modes

HEA

T mode

HORIZONTAL AIR FLOW DIRECTION

NOTE:

• The adjusted position will be memorized and will

be automatically set to the same position when

operated the next time.

1

2

ADJUSTING THE AIR FLOW

DIRECTION

CAUTION:

Never attempt to adjust the vertical adjustment lou-

vres manually.
• Manual adjustment of the vertical adjustment lou-

vre can cause the unit to malfunction when the

remote control is used for adjustment.

• When the vertical adjustment louvre is positioned

at the lowest position in the COOL or DRY mode

for an extended period of time, condensation may

result.

Do not adjust the horizontal adjustment louvre to the ex-

treme left or right in the COOL mode with the fan speed

set to “SOFT (

)” for an extended period of time.

Condensation may form on the louvres.

Hold the horizontal adjustment louvre as shown

in the diagram and adjust the air fl ow direction.

When using your air-condi-

tioner with multi-system

With a multi system air conditioner, mul-

tiple indoor units can be connected to

one outdoor unit. When the setting mode

differs among indoor unit(s), the indoor

unit(s) operated later may not work.
• When the indoor unit(s) is/are operating in

HEAT mode, the remaining unit(s) can not

operate in COOL or DRY mode.

• When the indoor unit(s) is/are operating in

COOL or DRY mode, the remaining unit(s)

can not operate in HEAT mode.

When the mode of the indoor unit(s) later op-

erated is/are different from those which is/are

in operation, after a few seconds, a long BEEP

will be emitted and the temperature indicator

on the indicator panel will indicate”

” and

the OPERATION lamp and TIMER lamp will

blink alternately. This shows that the later op-

erated unit(s) is/are not working. In such case,

change the mode to the same mode which the

other indoor unit(s) is/are operating in.

TIPS ABOUT AUTO MODE

In the AUTO mode, the temperature setting

and mode are automatically selected accord-

ing to the room temperature and outdoor

temperature when the unit is turned on.
• During operation, if the outdoor tempera-

ture changes, the temperature settings will

automatically slide as shown in the chart.

Modes and Temperature Settings

The fi gures in ( ) are temperature settings

• When using your air-conditioner with multi-

system, mode of the unit operated first

will have priority over other unit(s) without

reference to the above chart.

Advertising