18
Malfunctions
• F3 appears in the display.
– The appliance has suffered a fault. Contact the customer service
department.
You may be able to rectify the following faults by checking
the possible causes yourself.
• Appliance does not function:
– Is the appliance switched on?
– Is the plug correctly fitted in the mains socket?
– Is the fuse intact?
• When inserting the mains plug, the refrigeration unit does
not switch on, but a value is shown in the temperature
display.
– Demo mode is activated. Deactivate demo mode as described
in the section entitled Demo mode.
• Loud running noise:
– Is the appliance set up firmly on the floor?
– Does the appliance cause nearby items of furniture or objects to
vibrate? Please note that noises caused by the refrigerant circuit
cannot be avoided.
• The temperature is not low enough:
– Is the temperature setting correct (see "Setting the temperature")?
– Does the separately installed thermometer show the correct
reading?
– Is the ventilation system working properly?
– Is the appliance set up too close to a heat source?
If none of the above causes
apply and you cannot rec-
tify the fault yourself, contact
the nearest customer ser-
vice department stating the
type designation
1
, service
number
2
and appliance
number
3
as indicated on the
type plate.
The position of the type plate is shown in the section entitled
Description of the appliance.
Changing over door hinges
Shutting your appliance down
If your appliance is to be shut down for any length of time, switch
it off and disconnect the plug or switch off or unscrew the fuse.
Clean the appliance and leave the door open in order to prevent
unpleasant smells.
The appliance complies with the relevant safety regulations and
EC Directives 2004/108/EC and 2006/95/EC.
1. Unscrew the hinge bracket.
3. Transfer handle and plugs to the
opposite side of the door.
2. Pull the door out at the
bottom and lift off.
1
2
3