Section 7 - Lubrication and Maintenance

7-11

31200172

B. Element Change (as restriction indicator indicates)

1. Unlock air cleaner cover (4), turn counterclockwise and remove from air cleaner

canister (5).

2. Remove outer primary element (6) and inspect for damage. Damaged elements

should not be reused.

3. Thoroughly clean the interior of the air cleaner canister and vacuator valve.

4. Replace inner safety element (7) after every third primary element change. If

replacing the inner safety element at this time, carefully slide the element out
and replace with new element.

5. Slide the new primary element over the inner element making sure the sealing

edge is flush with the base of the air cleaner.

6. Position air cleaner cover in place, turn clockwise and lock into position.

7. Depress button on restriction indicator to reset.

Note: An inner safety element should never be washed or reused. Always install a
new element.