Defi ADVANCE Control Unit (DF07703 Manufactured in and before January, 2012) User Manual

Page 17

Advertising
background image

9. To confirm the wiring and connection, connect gauges and displays to the

control unit temporarily by using meter wires. Do not fix the gauge at this
stage.

Do not remove the convex connector if you use only one METER OUTPUT

connector to protect against short-circuit between two terminals.

10. Connect the negative battery terminal.

11. Confirm that the DC SOURCE LED is on when the ignition is on. If the

power supply wire is wired correctly, the DC SOURCE LED of the control unit
lights in blue. And also look see that CR gauges' illumination lights up/BF
gauges' illumination darkens/ZD's switch illumination lights up when the
illumination switch of the vehicle is on.

The DC SOURCE LED is not on: The power supply is not taken.

→ Turn the ignition off, then please confirm the wiring of the power supply wire.

The warning LED of gauge is blinking or the warning LED and peak LED are

blinking at the same time: disconnection, short circuit, or communication
error is occurred.
⇒ Refer to 7 -3-2. Error displays of wire disconnection, short circuit, and
serial error.

→ Turn the ignition off, then please confirm the wiring of the sensor and the

sensor wire.

Warning

If the wiring defects are not found, it is probable that there is a defect in the

product. Please detach the product immediately and ask for inspection. It
may damage the vehicle.
⇒ Refer to  Maintenance & Check & Servicing.

12. Turn the ignition OFF.

55

Advertising