15

This aerial work platform is manufactured with safety de-

vices, placards, and decals to reduce the likelihood of an

accident. For the safety of all personnel, do not disable,

modify, or ignore any safety device. Safety devices are

included in the daily prestart inspection.

Warning

The potential for an accident increases when safety

devices do not function properly. Death or serious

injury can result from such accidents. Do not alter,

disable, or override any safety device.

If any safety devices are defective, remove the aerial

platform from service until qualified maintenance person-

nel can make repairs.

Emergency Stop Controls

There is an emergency stop control at the lower and

upper controls.

At the lower controls, the emergency stop is a two-position

push button (refer to Figure 4.1). Push the emergency

stop button in to disconnect power to all control circuits.

Pull the button out to restore power.

Figure 4.1 – Lower Controls

Note

The lower controls override the upper controls. If the up-

per control emergency stop button is engaged, the lower

controls can still be used to operate the aerial platform.

At the upper controls, the emergency stop is a two-posi-

tion push button (refer to Figure 4.2).

Chapter 4 – Safety Devices

Figure 4.2 – Upper Controls

Push the emergency stop button in to disconnect power

to the upper control circuits. Pull the button out to restore

power.

Emergency Power System

The emergency power system includes a back-up pump,

motor, and battery. Use this system to operate the boom

and turntable functions to lower the platform if the main

power system fails due to engine or pump failure.

Hold the emergency power switch (refer to Figure 4.1

and 4.2) in the direction of the white arrow to activate the

emergency power system.

The length of time the pump can be operated depends

on the capacity of the battery.

Manual Emergency Lowering Pump

The manual emergency lowering pump may be used to

lower the riser and main booms if the engine will not start

and the emergency power system will not work. The pump

(refer to Figure 4.3) is behind the cowling door on the left

side of the turntable.

Figure 4.3 – Manual Emergency Lowering Pump

After selecting either the riser or main boom valve, the

hand pump may be used for emergency lowering.

Engine/Emergency

Power Switch

Ground

Operation Switch

Emergency

Stop Button

Engine/Emergency

Power Switch

Emergency

Stop Button

Pump

Manual Emergency

Lowering Pump

Riser Boom Knob

Main Boom Knob

Advertising