Electrical system – JLG 4013PS Service Manual User Manual
Page 213

9-73
3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9
Electrical System
TRANSMISSION A
COIL – SHORT TO
GROUND
33251
1
Deactivate output J2-33
Transmission A Control Coil.
Flash the “Gear Selection” and the
“Drive Direction” symbols on the
LCD of the cabin’s display.
A TRANSMISSION configuration of
POWERSHIFT is configured and
the UGM detects a short to ground
at this output.
Power cycled.
TRANSMISSION
FORWARD COIL –
OPEN CIRCUIT
33252
1
Deactivate output J2-33
Transmission Forward Coil.
Flash the “Gear Selection” and the
“Drive Direction” symbols on the
LCD of the cabin’s display.
A TRANSMISSION configuration of
HYDROSTATIC is configured and
the UGM detects an open circuit at
this output.
Power cycled.
TRANSMISSION
FORWARD COIL –
SHORT TO
BATTERY
33253
1
Deactivate output J2-33
Transmission Forward Coil.
Flash the “Gear Selection” and the
“Drive Direction” symbols on the
LCD of the cabin’s display.
A TRANSMISSION configuration of
HYDROSTATIC is configured and
the UGM detects a short to battery
at this output.
Power cycled.
TRANSMISSION
FORWARD COIL –
SHORT TO
GROUND
33254
1
Deactivate output J2-33
Transmission Forward Coil.
Flash the “Gear Selection” and the
“Drive Direction” symbols on the
LCD of the cabin’s display.
A TRANSMISSION configuration of
HYDROSTATIC is configured and
the UGM detects a short to ground
at this output.
Power cycled.
TRANSMISSION E
COIL –
OPEN CIRCUIT
33255
1
Deactivate output J1-7
Transmission E Control Coil (Gear
will not be available for selection).
3
rd
and 4
th
will be the only available
gear selections.
Flash the “Gear Selection” symbol
on the LCD of the cabin’s display.
A TRANSMISSION configuration of
POWERSHIFT is configured and
the UGM detects an open circuit at
this output.
Power cycled.
TRANSMISSION E
COIL – SHORT TO
BATTERY
33256
1
Deactivate output J1-7
Transmission E Control Coil.
Flash the “Gear Selection” symbol
on the LCD of the cabin’s display.
A TRANSMISSION configuration of
POWERSHIFT is configured and
the UGM detects a short to battery
at this output.
Power cycled.
TRANSMISSION E
COIL – SHORT TO
GROUND
33257
1
Deactivate output J1-7
Transmission E Control Coil.
3
rd
and 4
th
will be the only available
gear selections.
Flash the “Gear Selection” symbol
on the LCD of the cabin’s display.
A TRANSMISSION configuration of
POWERSHIFT is configured and
the UGM detects a short to ground
at this output.
Power cycled.
TRANSMISSION 1
COIL –
OPEN CIRCUIT
33258
1
Deactivate output J1-7
Transmission 1 Coil.
Maintain the last valid gear
selection.
Flash the “Gear Selection” symbol
on the LCD of the cabin’s display.
A TRANSMISSION configuration of
HYDROSTATIC is configured and
the UGM detects an open circuit at
this output.
Power cycled.
TRANSMISSION 1
COIL – SHORT TO
BATTERY
33259
1
Deactivate output J1-7
Transmission 1 Coil.
Deactivate and inhibit activation of
J1-20 Transmission 2 Coil.
Flash the “Gear Selection” symbol
on the LCD of the cabin’s display.
A TRANSMISSION configuration of
HYDROSTATIC is configured and
the UGM detects a short to battery
at this output.
Power cycled.
Message
Fault
Code
Indicators
Other Actions Taken
Trigger for Fault
Latch Until